Permit Info
Short Description:
*VOID*4311 AC, 5174 SF, SFR / 2 STORY
Notes:
*VOID*4311 AC, 5174 SF, SFR / 2 STORY
8/10/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. BEAMS=8"W X 30"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
030. 1ST FLOOR WINDOW BOX-OUTS MUST HAVE MASONRY BELOW.
032. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
DOMINION AT PANTHER CREEK #4A (CFR)
|
APPLICANT | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #600 | DALLAS, TX 75248 |
OWNER | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #600 | DALLAS, TX 75248 |
CONTRACTOR | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #600 | DALLAS, TX 75248 |
HERS PROVIDE | ACP ALLIED CONSTRUCTION PROFES | (214)227-9540 | TONYA@ENERGYACP.COM | 1900 ESPINOSA DRIVE | Carrollton, TX 75010 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | TAMI@STRANDSYSTEMS.COM | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | STAFFORD, TX 77477 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | TEXAS UNITED EXCAVATORS | (972)446-2500 | DIANA@TUEXCAVATORS.COM | 1451 HALSEY WAY | CARROLLTON, TX 75007 |
|
RESIDENTIAL ELECTRIC FEE |
$155.22
|
|
MISCELLANOUS MECHANICAL FEES |
$129.50
|
|
MISCELLANEOUS PLUMBING FEES |
$239.00
|
|
BUILDING PERMIT FEE |
$2,103.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $2,647.47
Balance Due: $2,647.47
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Michelle Ortega | | 8/4/2010 | | 8/25/2010 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | Approved as Noted | 8/4/2010 | 8/4/2010 | 8/25/2010 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | VOID | 10/13/2010 | 10/13/2010 | 11/2/2010 |
More Info
|