Notes:
ALL WORK PERFORMED MUST MEET THE 2006 INTERNATIONAL BUILDING CODE, LOCAL AMENDMENTS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE AND ALL OTHER CITY ORDINANCES.
*** PLANS PROVIDE LIMITED INFORMATION ABOUT INSTALLATION METHODS AND DESIGN FOR ELECTRICAL AND PLUMBING SCOPE. PERMIT SHALL BE SUBJECT IN WHOLE TO FIELD INSPECTION AND APPROVAL. PERMIT APPROVAL DOES NOT IMPLY APPROVAL OF INSTALLATION METHODS AND DESIGN BASED ON LIMITED INFORMATION PROVIDED.
*** SEWER LATERIAL AND WASTE NOT ACCEPTABLE AND NOT ISSUED AS A PORTION OF THIS PERMIT. CONNECTION AND PUBLIC IMPROVEMENT MUST BE INSTALLED AS A PORTION OF PUBLIC WORKS ACCEPTANCE PRIOR TO APPROVAL AND INSTALLTION OF SEWER CONNECTIONS TO FOUNTIAN. *** RESUBMIT AFTER PUBLIC WORKS ACCEPTANCE ***
ELECTRICAL WILL BE DESIGNED AND INSTALLED PER THE 2005 NATIONAL ELECTRICAL CODE WITH LOCAL AMENDMENTS STATED IN CITY OF FRISCO ORDINANCE ALONG WITH THE FOLLOWING COMMENTS.
1. MINIMUM #12 COPPER CONDUCTORS PERMITTED EXCEPT FOR CONTROLS.
2. NO ALUMINUM WIRE PERMITTED.
3. PULL EQUIPMENT GROUNDS IN ALL RACEWAYS.
4. SUBJECT TO FIELD INSPECTION.
PLUMBING WILL BE DESIGNED AND INSTALLED PER THE 2006 INTERNATIONAL PLUMBING CODE WITH LOCAL AMENDMENTS STATED IN CITY OF FRISCO ORDINANCE ALONG WITH THE FOLLOWING COMMENTS.
1. ALL SUBJECT TO FIELD INSPECTIONS AND TESTING.
2. BELOW GRADE PIPING TO BE BEDDED WITH SAND.
3. TRENCHES TO BE COMPACTED AT BACKFILL.
4. RPZ REQUIRED AT WATER SUPPLY FOR FOUNTIAN EQUIPMENT.
***FOUNTIAN DEPTH LIMITED TO 18"
***SIDEWALKS TO MEET CITY ENGINEERING STANDARDS.
841 SQ FT, CNEW / PARK PLACE ESTATES GAZEBO & FOUNTAINS