Notes:
399399 SQ FT, CALT / STONEBRIAR CHEVROLET SPRAY BOOTH
7/15/2010 12:00:00 AM
1] 416.2 Spray rooms. Spray rooms shall be enclosed with fire barriers with not less than a 1-hr fire-resistance rating.
2]Floors shall be waterproofed and drained in an approved manner.
3] 416.2.1 Surfaces. The interior surfaces of spray rooms shall be smooth and shall be constructed to permit he free passage of exhaust air from all parts of the interior and to facilitate washing and cleaning, and shall be so designed to confine residues within the room. Aluminum shall not be used.
4] 416.3.1 Surfaces. The interior surfaces of spraying spaces shall be smooth and continuous without edges.
5] shall be so constructed to permit the free passage of exhaust air from all parts of the interior and to facilitate washing and cleaning; and shall be designed to confine residues within the spraying space. Aluminum shall not be used.
6] 416.4 Fire protection. An automatic fire-extinguishing system shall be provided in all spray, dip and immersing spaces and storage rooms and shall be installed in accordance with chapter 9.