Notes:
384 SQ FT, SALT / ARBOR & CONCRETE PAD
6/24/2010 12:00:00 AM
1. ATTACH NEW ARBOR TO EXISTING PATIO COVER.
2. GUSSET PLATES MAY BE REQ'D. FOR ATTACHMENT ON THE BACKSIDE OF THE 4X12 BEAM AND 4X8 BEAM.
THESE BEAMS SHALL BE SUPPORTED WITH 8X8 POSTS.
3. THE EXISTING PATIO COVER WAS NOT DESIGNED TO CARRY THE EXTRA DEAD LOAD OF THE NEW ARBOR.
4. ATTACHMENT TO EXISTING PATIO COVER IS PERMISSABLE BUT THE NEW ARBOR SHALL BE SELF SUPPORTING.
5. FOOTER INSPECTION IS REQ'D. 16" WIDE FOOTER EACH WAY IS REQ'D. 30" DEEP.
6. FASTENING METHODS SHALL COMPLY WITH SECTION 802 2006 IRC.
7. THE INSPECTOR MUST BE ABLE TO SEE METOD OF ATTACHMENT AT ALL LOCATIONS.
8. ALL WORK MUST BE INSPECTED AND APPROVED BY A CITY OF FRISCO INSPECTOR.
9. SIMPSON BRACKETS OR PRESSURE BLOCKING IS ALLOWED AND SHALL BE USED WHEN CONNECTING THE 2X10'S TO BEAMS OR HEADERS. SEE NOTE 7 ABOVE.
10. MINIMUM 10' REQUIREMENT FROM FACE OF SUPPORTING COLUMN/POST TO REAR PROPERTY LINE. EAVE PORTION MAY ENCROACH A MAXIMUM OF 3'.
11. ANY CHANGES RELATING TO STAMPED PLANS WILL REQUIRE REVISIONS AND RED TAG. PLANS TO REMAIN ON SITE THROUGHOUT CONSTRUCTION.
12. CEMENT SHALL BE 4" THICK MINIMUM WITH SPACING OF #3 REBAR @ 18" O.C.E.W. WITH EXPANSION JOINTS.
INSPECTIONS REQ'D.
PRE-POUR
MISC. FRAME
MISC. BLDG. FINAL
13. NO ELECT. OR PLBG. IN SCOPE OF WORK.