Short Description:
400 SQ FT, SALT / ARBOR, KITCHEN, 7FT WALL & CONCRETE
Notes:
400 SQ FT, SALT / ARBOR, KITCHEN, 7FT WALL & CONCRETE
7/6/2010 12:00:00 AM
1. ALL WORK SHALL BE FIELD VERIFIED BY A CITY INSPECTOR.
2. ALL WORK SHALL COMPLY WITH CURRENT I-CODES AND LOCAL ADOPTED AMENDMENTS.
3. NO PLBG. IN SCOPE OF WORK. THERE IS A 3' FLEX LINE TO BE INSTALLED AT GRILL, NO INSPECTION REQ'D. THERE MUST BE A VALVE AT THE GAS LINE AS IT EXITS THE HOUSE. IF THERE IS NOT THEN A PLBG. PERMIT IS REQ'D. TO INSTALL THE VALVE.
4. THERE IS ELECTRICAL AT THE GRILL, AN ELECTRICAL GFI PROTECTED OUTLET.
5. ALL FOOTING INSPECTIONS SHALL BE INSPECTED AT THE SAME TIME.
6. DO NOT ATTACH ARBOR TO EXISTING FASCIA/SOFFIT. THIS EXISTING AREA OF FRAMEWORK WILL NOT SUPPORT THE EXTRA LOAD.
7. INSPECTOR MAY NEED TO SEE METHOD OF LEDGER BOARD TO EXISTING RAFTERS.
8. RECOMMENDATION TO SLOPE NEW LANDSCAPE BEDDING AWAY FROM SLAB 6" IN 10' TO PREVENT PONDING OF WATER NEXT TO SLAB.