Notes:
248 SQ FT, SALT / COVERED PATIO
3/4/2010 12:00:00 AM
1. ALL WORK SHALL COMPLY WITH CURRENT CODES AND LOCAL AMENDMENTS.
IRC 2006----------216 SQ. FT STRUCTURE, MAINTAIN 20' REAR BUILD LINE; MEASURE TO FACE OF POST, THE EAVE PORTION MAY ENCROACH A MAXIMUM OF 3'.
2. ALL WORK SHALL BE INSPECTED.
3. ROOF SLOPE SHALL BE 1/4 " PER FOOT MINIMUM.
4. ALL WOOD SHALL BE PRESSURE TREATED.
5. PER CONVERSATION THE CONCRETE PATIO DECK MAY CHANGE DIMENSIONS-----NEED TO VERIFY AT SITE.
6. NO ELECTRICAL WORK SHOWN.
INSPECTIONS REQ'D:
A. FOOTER
B. PRE-POUR [SLAB] ----FORM UP AND PLACE #3 REBAR CHAIRED, AND 18" O.C.E.W. REBAR SPACING WITH MAXIMUM 1" SAND CUSHION.
EXPANSION JOINT BETWEEN OLD/NEW CONCRETE TRANSITION. IT IS RECOMMENDED TO DRILL AND EXPOXY #3 OR #5 SMOOTH DOWELS INTO EXISTING SLAB.
C. MISC. FRAME
D. MISC. BLDG. FINAL
7. PLANS TO REMAIN ON SITE FOR THE INSPECTOR AND PERMIT PLACARD SHALL BE ACCESSIBLE.