Notes:
1536 SQ FT, TEMP / CHRISTIE ELEMENTARY (one portable @ west)
9/9/2009 12:00:00 AM
REVISED SITE PLAN EXPIRES 08/24/2011.
THESE REQ'MENTS WILL BE FIELD VERIFIED.
PORTABLE EDUCATION BLDG.
MINIMUM OF 20' SEPARATION BETWEEN SCHOOL AND PORTABLE. BLDG.
A. CONTINGENT UPON COMPLIANCE WITH BLDG CODES & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
B. ALL PARTS OF THE BLDG ENVELOPE MUST MATCH OR EXCEED THE MIN. INSULATION REQUIREMENTS OF IECC, WITH R-13 FOR WALLS, R-19 FOR ROOF.
C. SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
ALL SUBCONTRACTORS MUST VALIDATE AND OBTAIN CURRENT REGISTRATION WITH THE CITY PRIOR TO START OF PROJECT.
F. INTERIOR FINISHES: GROUP-E CLASS--B
FLAME SPREAD ------------ 25 TO 76
SMOKE DEVELOPED------- 0 TO 450
J. WHERE ABOVE CEILING AREA IS USED AS HVAC PLENUM-ALL WIRING SHALL BE PLENUM RATED.
L. MILLWORK TO MEET ADA/TAS REQUIREMENTS
EXISTING PLBG. FIXTURES SHALL ACCOMODATE ADDITIONAL STUDENT OCCUPANT LOAD. THE MAXIMUM DISTANCE NOT MORE THAN 500' FROM PORTABLE BLDG. AND SCHOOL RESTROOMS. WHERE EXISTING PLBG. FIXTURE COUNT AND ADDITIONAL OCCUPANT LOAD DO NOT CORRELATE, REVISIONS AND PROVISIONS SHALL BE MADE TO COMPLY WITH THE 2006 IPC.