Notes:
252 SQ FT, SADD / ARBOR, FIREPLACE & GRILL
8/24/2009 12:00:00 AM
ALL WORK PERFORMED MUST MEET THE 2006 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
*FIRE PIT NOT REQUESTED OR PERMITTED. ***
* FIREPLACE MUST BE 100% MASONRY.
* VENTING AND FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
* MUST MAINTAIN TEN FOOT CLEARANCE FROM ALL COMBUSTABLE ITEMS.
* CHIMNEY MUST MAINTAIN A MINIMUM OF 2' IN CLEARANCE (EXCLUDING SPARK ARRESTOR) IN HEIGHT WITHIN A 10' RADIUS OF CHIMNEY.
* FOOTER THICKNESS 12" MIN & WIDTH 6" EACH SIDE OF FIREPLACE WALL.
* OUTSIDE OF POST / FIREPLACE OR GRILL CAN NOT ENCROACH THE 10' REAR PROPERTY LINE.
* OUTSIDE OF POST / FIREPLACE OR GRILLCAN NOT ENCROACH THE 15' SIDE YARD SETBACK.
*** EXISTING BRICK IS NOT DESIGNED TO CARRY ADDITIONAL DEAD LOADS.
*** OPTIONS FOR ATTACHMENT OF ARBOR:
A. LEDGER BOARD ATTACHED TO BRICK WITH 3/8" X 10" LAGS THRU BRICK TO VERTICAL STUDS.
B. PRESSURE BLOCK BETWEEN RAFTERS SAME PRINCIPLE NOTE A.
C. LEDGER BOARD ATTACHED PERPENDICULAR TO EXISTING ROOF LINE RAFTERS WITH 3/8" X 6" LAGS.
*** SIMPSON BRACKETS EPB OR PB OR TYPE U-SHAPED SHALL BE USED TO ATTACH COLUMNS TO CONCRETE PATIO DECK.
* PLANS TO REMAIN ON SITE THROUGHOUT CONSTRUCTION.
SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
INSPECTIONS REQ'D:
MISC FRAMING / PLUMBING ROUGH / ELECTRICAL ROUGH
MISC BUILDING FINAL / ELEC FINAL / PLUMB FINAL
CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.