Notes:
136 SQ FT, SADD / BALCONY W/ PATIO COVER; FIREPIT
8/31/2009 12:00:00 AM
1. FIRE PITS SHALL HAVE A MINIMUM DISTANCE OF 15' FROM MAIN STRUCTURE AND 10' FROM ANY COMBUSTIBLES. ART. IV SECT. 7 CZO.
2. IRC 2006 SECTION R311. 5.8.1. MINIMUM WIDTH SHALL BE 26" W/EACH TREAD HAVING 7 1/2" MINIMUM TREAD DEPTH @ 12" FROM THE NARROWER EDGE. ALL TREADS IDENTICAL, RISE NO MORE THAN 9 1/2". A MINIMUM HEADROOM OF 6'-6" SHALL BE PROVIDED.
3. ALL WORK SHALL BE INSPECTED AND SHALL COMPLY WITH 2006 IRC SECTION 301 & CHAPTERS 8, 9.
4. ROOF IS ENGINEERED, SEE ATTACHED EOR LETTER.