Notes:
160 SQ FT, SADD / PATIO COVER
6/29/2009 12:00:00 AM
ALL WORK PERFORMED MUST MEET THE 2006 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
* NO ELECTRICAL OR PLUMBING PERMIT REQUESTED OR ISSUED ***
* FIREPLACE, FIRE PIT, OUTDOOR KITCHEN (BBQ GRILL, SINK, ETC) NOT REQUESTED OR PERMITTED. ***
* OUTSIDE OF POST CAN NOT ENCROACH THE 20' REAR YARD SETBACK.
* OUTSIDE OF POST CAN NOT ENCROACH THE 7' SIDE YARD SETBACK.
*** EXISTING SOFFIT [CORNICE] IS NOT DESIGNED TO CARRY ADDITIONAL DEAD LOADS.
*** OPTIONS FOR ATTACHMENT OF NEW PATIO COVER:
A. LEDGER BOARD ATTACHED TO BRICK WITH 3/8" X 10" LAGS THRU BRICK TO VERTICAL STUDS.
B. PRESSURE BLOCK BETWEEN RAFTERS SAME PRINCIPLE NOTE A.
C. LEDGER BOARD ATTACHED PERPENDICULAR TO EXISTING ROOF LINE RAFTERS WITH 3/8" X 6" LAGS.
*** SIMPSON BRACKETS EPB OR PB OR TYPE U-SHAPED SHALL BE USED TO ATTACH COLUMNS TO CONCRETE PATIO DECK.
* PLANS TO REMAIN ON SITE THROUGHOUT CONSTRUCTION.
SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
INSPECTIONS REQ'D:
MISC BUILDING FINAL
CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.