Notes:
503 SQ FT, SADD / PATIO COVER & ARBOR W/ GRILL & FIREPLACE
6/23/2009 12:00:00 AM
* ALL WORK PERFORMED MUST MEET THE 2006 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
* OUTSIDE OF POST CAN NOT ENCROACH THE 10' REAR YARD SETBACK.
* OUTSIDE OF POST CAN NOT ENCROACH THE 7' SIDE YARD SETBACKS.
* FIREPLACE CAN NOT ENCROUCH 10' REAR PROPERTY LINE OR 7' SIDE YARD SETBACK.
*** FIRE PIT NOT REQUESTED OR PERMITTED. ***
* FIREPLACE MUST BE 100% MASONRY.
* COMPLY WITH CHAPTER 10 OF THE 2006 IRC.
* VENTING AND FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
* MUST MAINTAIN TEN FOOT CLEARANCE FROM ALL COMBUSTABLE ITEMS.
* CHIMNEY MUST MAINTAIN A MINIMUM OF 2' IN CLEARANCE (EXCLUDING SPARK ARRESTOR) IN HEIGHT WITHIN A 10' RADIUS OF CHIMNEY.
* FOOTER THICKNESS 12" MIN & WIDTH 6" EACH SIDE OF FIREPLACE WALL.
SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION.
INSPECTIONS REQ'D:
ELECRICAL ROUGH / PLUMBING ROUGH / MISC FRAMING
MISC BUILDING FINAL / ELEC FINAL / PLUMB FINAL
CITY OF FRISCO APPROVAL IS NOT IN LIEU OF HOMEOWNER ASSOCIATION (HOA) REQUIREMENTS. REFERENCE HOA BYLAWS FOR SUBDIVISION REQUIREMENTS.