Permit Info
Short Description:
4784 AC, 5942 SF, SFR / 2 STORY*****VOID**SEE B09-0737******
Notes:
4784 AC, 5942 SF, SFR / 2 STORY*****VOID**SEE B09-0737******
2/20/2009 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
SHADDOCK CREEK ESTATES PH 2
|
APPLICANT | NEWCASTLE HOMES | (214)987-9158 | | 8333 DOUGLAS AVE, # 1500 | DALLAS, TX 75225 |
OWNER | NEWCASTLE HOMES | (214)987-9158 | | 8333 DOUGLAS AVE, # 1500 | DALLAS, TX 75225 |
CONTRACTOR | NEWCASTLE HOMES | (214)987-9158 | | 8333 DOUGLAS AVE, # 1500 | DALLAS, TX 75225 |
HERS PROVIDE | TEXENERGY SOLUTIONS | (972)579-2009 | SELLISON@TEXENERGY.ORG | 2611 E. PIONEER | IRVING, TX 75061 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
ELECT. CTR. | POTTER ELECTRIC | (972)442-1600 | | 10077 RETTOP RD | LAVON, TX 75166 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2013 | DAVID.GANNON@TEMPOAIR.COM | P.O. BOX 155049 | IRVING, TX 75015 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | | 900 ALPHA #430 | RICHARDSON, TX 75081 |
|
RESIDENTIAL ELECTRIC FEE |
$178.26
|
|
MISCELLANOUS MECHANICAL FEES |
$175.50
|
|
MISCELLANEOUS PLUMBING FEES |
$312.00
|
|
BUILDING PERMIT FEE |
$2,278.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $2,964.51
Balance Due: $2,964.51
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Michelle Ortega | Accepted | 2/17/2009 | 2/17/2009 | 3/10/2009 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | Approved as Noted | 2/17/2009 | 2/20/2009 | 3/10/2009 |
More Info
|