Permit Info
Short Description:
*EXPIRED*4904 AC, 6369 SF, SFR / 2 STORY
Expiration Date:
8/5/2009
Notes:
*EXPIRED*4904 AC, 6369 SF, SFR / 2 STORY
2/6/2009 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(2/6/2009 13:05 JC)
Grade Beam(s) : upper found. 10"w. x 28" d. Lower found. 12" x 30" d.
Grade Beam Rebar : Upper Beam (2) PT strands + (2) #5 rebar
" " " : Lower Beam (2) #5 rebar, top and bottom of beam
Parcel Info
Subdivision:
SHADDOCK CREEK ESTATES PH 5
|
APPLICANT | FOUNTAIN CREEK CUSTOM HOMES LL | (214)636-4465 | DGORDEN@FOUNTAINCREEKVILLAS.COM | 8261 CRIPPLE CREEK | Frisco, Tx 75034 |
OWNER | GORDEN, JASON | ()- | | 8261 CRIPPLE CREEK DR | FRISCO, TX 75034 |
CONTRACTOR | FOUNTAIN CREEK CUSTOM HOMES LL | (214)636-4465 | DGORDEN@FOUNTAINCREEKVILLAS.COM | 8261 CRIPPLE CREEK | Frisco, Tx 75034 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | INFORMATION@METROCODE.COM | 2630 W FREEWAY, SUITE 200 | FT WORTH, TX 76102 |
STRUCT ENG | PARAGON STRUCTURAL ENGINEERING | (214)941-8350 | brian@pseglobal.com | 5068 W PLANO PKWY, SUITE 199 | PLANO, TX 75093 |
ELECT. CTR. | FRISCO ELECTRIC, INC | (214)387-7878 | MVBREWER@FRISCOELECTRIC.COM | 6811 PECAN ST | FRISCO, TX 75035 |
MECH. CTR. | COOL BREEZE SERVICES | ()- | | | |
PLUM. CONT. | FRITZ PLUMBING | (972)335-3560 | THOMAS@FRITZPLUMBING.COM | P.O. BOX 194 | FRISCO, TX 75034 |
|
RESIDENTIAL ELECTRIC FEE |
$191.07
|
|
MISCELLANOUS MECHANICAL FEES |
$175.50
|
|
MISCELLANEOUS PLUMBING FEES |
$298.00
|
|
BUILDING PERMIT FEE |
$2,323.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $3,008.32
Balance Due: $3,008.32
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Andrew D Edwards | | 2/4/2009 | | 2/25/2009 |
More Info
|
RESIDENTIAL REVIEW | Jim Cottone | Approved as Noted | 2/4/2009 | 2/6/2009 | 2/25/2009 |
More Info
|
MISC REVIEW | Michele Wood | N/A | 4/1/2009 | 4/1/2009 | |
More Info
|