Notes:
SADD / REMODEL 1910 SQ. FT. A/C
1/27/2009 12:00:00 AM
001. HOUSE MUST MEET GREEN BUILDING ORDINANCE REQ'MENTS, ALLOWING FOR FRESH AIR TO EACH HVAC UNIT WITH TWO DAMPERS (MANUAL AND AUTOMATIC)---------------NO THIRD PARTY OR REM-RATE REQ'D---PLANS MUST MEET 2006 IECC REQ'MENTS.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. IF APPLICABLE-----TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
044. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
055. FUEL BURNING HOT WATER HEATER INSTALLATION MUST BE CODE COMPLIANT.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL---THIS APPLIES TO NEW PORTION ONLY.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF THIS ISSUED BUILDING PERMIT---EACH ENG. DWG. IS SEALED BY THE ENGINEER.
INSTALL FLOOR DRAIN U/S LAUNDRY
FIRST FLOOR INCLUDES PWDR BATH, VESTIBULE, THEATER.
2ND FLOOR INCLUDES PLAY RM., LAUNDRY, EXERCISE RM. & BATH.
BOTH PATIO COVERS AND OUTDOOR FIREPLACE CONSTRUCTION INCLUDED IN THIS PERMIT