Notes:
B08-3782
CHRISTIE ELEMENTARY
SHADE STRUCTURE
1188 SQ. FT.
1. RECOMMENDATION: WOOD CHIPS HAVE BEEN KNOWN TO BE COMBUSTIBLE IN EXTREME HEAT, BE AWARE OF SAFETY FACTORS.
2. PER ATTACHED DOCUMENT: AWNING FABRIC SHALL BE FIRE-RETARDENT. (THIS IS FILED WITH THE City of Frisco)
3. SUBJECT TO FIELD APPROVED INSPECTIONS AND TESTING.
4. PIER INSPECTION IS REQ'D.
5. CONSTRUCTION SHALL COMPLY WITH MANUFACTURERS INSTRUCTIONS AND WITH IBC 2006 CHAPTER 16 AND SECTION 31. 1607.11.2.4 AWNINGS AND CANOPIES SHALL BE DESIGNED FOR A UNIFORM LOAD OF 5 PSF ROOF LOAD MINIMUM.
6. WIND DESIGN LOAD CATEGORY: 90 MPH 3 SEC. GUST, SEISMIC DESIGN CATEGORY B. EXPOSURE C. SECTION 1609 WIND LOADS
(LATERAL FORCES) NOT LESS THAN 10 PSF.
INSPECTIONS REQ'D.
1. FOOTER
2. MISC. BLDG. FINAL
1188 SQ FT, SCHA / CHRISTIE ELEMENTARY SHADE COVER