Notes:
1. DWGS TO REMAIN ON SITE OR PERMIT IS NULL AND VOID.
2. NO BRICK PERMITTED FOR NEW ENCLOSED NON-A/C SUN ROOM, SIDING ONLY DUE TO ADDITIONAL LIVE AND DEAD LOADS. THEY ARE PERMITTED TO INSULATE THIS ROOM. THIS MUST BE NON-A/C SPACE OR HOMEOWNER WILL HAVE TO RESUBMIT FOR A/C AREA WHERE ELECTRICAL AND MECHANICAL ARE ADDED.
3. NO OVER SPAN ALLOWED ON HEADER BEAMS FOR PATIO COVER, SPEC SHEET INCLUDED FOR METAL HEADER BEAM. THIS PATIO COVER IS NOT AN ENGINEERED STRUCTURE, THE HOMEOWNER CHOSE TO USE AN ENGINEERED BEAM TO SPAN 29'-9".
4. SPIRAL STAIRS TO BE REMOVED.
5. ALL METAL WITHIN 5' FROM POOL SHALL BE BONDED TO BELLY STEEL.
6. POOL BUILT IN 1999-2000, ALL INSPECTIONS INCLUDING BELLY AND DECK STEEL WERE APPROVED. HOMEOWNER INDICATING WITH SUBMITTAL THAT THE EXISTING DECK WILL BE REMOVED AND STAMPED///PATTERNED CONCRETE TO BE SET. THIS NEW DECK AREA MUST BE BONDED TO EXISTING BELLY STEEL.
7. ADDING ENCLOSED SUNROOM AT EXISTING 2ND LEVEL BALCONY.
8. ALL WORK SUBJECT TO APPROVED FIELD INSPECTIONS AND TESTING.
9. NO ADDED MECH. OR PLBG. DEVICES.
10. NO PART OF NEW STRUCTURES CAN ENCROACH OVER SIDE YARD OF 7'.
3-17-09 ADDENDUM TO THIS PERMIT, ADDING FIREPLACE AND OUTDOOR KITCHEN
1. ALL WORK SHALL COMPLY WITH CURRENT I-CODES AND LOCAL AMENDMENTS (2006 IBC, IPC, IMC AND IRC)
2. ALL WORK SHALL BE FIELD APPROVED AND TESTED.
3. INSPECTIONS REQ'D. BUT NOT LIMITED TO:
PLBG. ROUGH
ELECT. ROUGH
FRAME
PLBG. FINAL
ELECT. FINAL
MISC. BLDG. FINAL
4. GAS LINES SHALL BE HARD PIPE, NO CANISTERS ALLOWED.
THESE PLBG/MECH. FIXTURES ARE PERMANENT, NOT PORTABLE.
5. FLEX GAS LINE MAX. IS 3 FEET.
6. PLANS SHALL REMAIN ON SITE THROUGHOUT CONSTRUCTION FOR CITY INSPECTORS.
7. LEAVE PLANS IN VISIBLE SIGHT.
8. ANY CHANGES TO THIS PERMIT SUBMITTAL SHALL BE APPROVED THROUGH PLAN REVIEW @ THE CITY OF FRISCO.
750 SQ FT, SADD / 2ND FLOOR ADDITION & PATIO COVER