Notes:
4105 SF, CNEW / NEWMAN VILLAGE AMENITY CENTER (discovery)
10/10/2008 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
49. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
50. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
58. 2006 IECC & ENERGY STAR COMPLIANCE REQUIRED.
(10/10/2008 08:43 JC)
1. Grade Beams : 12" w. x 36" d.
2. Sht. S2 "Found. design details" per 2006 IBC (not) 2000 IRC.
3. 5/8" type "x" sheet rock required in all area's.
4. CO detectors - 1 / 1000 sf of AC (4) req'd. this design.
5. Hand held fire extinguisher's req'd. location and number by the fire marshal.
6. Cool Roof req'd. - solar reflectance value of .25, .15 after (3) years. Documentation req'd. from mfg. prior to CO request.
7. Code compliance includes both the 2006 IRC and UBC.