Notes:
4372 AC, 5223 SF, SALT / FIRE RESTORATION
7/3/2008 12:00:00 AM
FIRE RESTORATION-----------------------
ALL WORK SUBJECT TO FIELD APPROVED INSPECTIONS.
SITE VISIT MADE BY MIKE CRAIN AND JEFF MAXWELL
THIS HOUSE WILL BE GRANDFATHERED AND THERE ARE NO ENERGY STAR REQ'MENTS OTHER THAN MEETING THE MINIMUM STANDARD FOR THE 2006 IECC.
ENGINEER APPROVAL ON FRAME IS REQ'D. BEFORE A CITY INSPECTOR CAN PERFORM THE 2NDS INSPECTION.
02. COMPLIANCE WITH THE APRIL 2006 IRC AND CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
38. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
55. FUEL BURNING HOT WATER HEATER INSTALLATION MUST BE CODE COMPLIANT.