Notes:
600 SQ FT, SADD / 72 SQ.FT. PORCH (T.U.R. 5188)
4/17/2008 12:00:00 AM
WORK STARTED W/O PERMIT:
ELECTRICAL OUTLETS MUST BE INSTALLED WITHIN 2' OF A DOOR AND EVERY 12'.
ALL OUTLETS IN MSTR. BDRM. MUST ARC-FAULT PROTECTED.
ALL WORK MUST COMPLY WITH 2006 IRC, 2005 NEC, IMC 2006.
ALL CONSTRUCTION SHALL BE FIELD VERIFIED AND TESTED BY CITY INSPECTIONS.
02. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.