Notes:
370 AC,(4334)SF, SADD / GAMERM EXTENSION & BATHRM RENOVATION
9/5/2007 12:00:00 AM
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
60. BUILDER CAUTION: CONSTRUCTION NOT CONFORMING TO THE ABOVE PERMIT REQUIRMENTS COULD RESULT IN C.O. DELAY OR POSSIBLE DENIAL.
2ND LEVEL: EXTEND GAME RM. AND REMODEL EXISTING BATH (ADDING W/C AND SHOWER)----------------------PLANS DO NOT INDICATE LOCATION OF NEW BATH IN RELATION TO EXISTING GAME RM. IF THIS IS A BDRM. W/(CLOSET) THEN A 5.7 SQ.FT EGRESS AT WINDOW IS REQ'D.