Notes:
1500 SQ FT, CALT / SALON LA BELLA
8/6/2007 12:00:00 AM
*** Building permit limited to framing of existing wall after installation of new plumbing systems and replacement of drywall. ***
*** No new or relocated walls associated with permit. ***
1. 1 hour fire/smoke construction w/ 3 5/8” metal studs w/ 5/8” type X gypsum on both sides up to deck---UL U465---fire caulk floor to deck.
2. ALL SUBJECT TO FIELD INSPECTIONS AND TESTING.
3. ALL CONNECTIONS TO EXISTING PLUMBING SHALL BE ACCESSIBLE AT INSPECTION.
4. ALL SOLDERED JOINTS SHALL BE MADE WITH FLUX CONFORMING TO ASTM B 813.
5. BACKFLOW PREVENTION REQUIRED FOR EQUIPMENT CONNECTED TO DOMESTIC WATER THAT DOES NOT HAVE INTEGRALLY INSTALLED BACKFLOW PROTECTION BUILT INTO EQUIPMENT. *** ALL SHAMPOO BASINS REQUIRES ABV DEVICE. ***
6. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRESTOPED BY APPROVED METHOD FOR MATERIAL.