Notes:
4724 AC, 6842 SF, SFR / 1 STORY
7/24/2007 12:00:00 AM
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
42. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. COMPLIANCE WITH THE US DEPT OF ENERGY (01/23/06 REQUIRMENTS) AND 2003 IECC REQUIRED.
(7/24/2007 09:02 JC)
Grade Beams : 8" w. x 20" d. Inspector Note : varify at frame inspection that limited storage area above the garage is framed at 20 PSF live load. Builder / Home Owned Note : Converting as little as 140 sf of limited storage above the garage to living area will require the entire house and garage to be protected by an automatic fire protection sprinkler system.