Permit Info
Short Description:
See B08-3728/ COMPASS CHRISTIAN CHURCH
Expiration Date:
3/10/2008
Notes:
See B08-3728/ COMPASS CHRISTIAN CHURCH
4/2/2007 12:00:00 AM
PLAN REVIEW COMMENTS;
1. ON CITY OF FRISCO AMENDMENTS SECTION 903.2.10.4 #3 REQUIRES THAT AN EXISTING BUILDING SHALL BE PROVIDED WITH AUTOMATIC FIRE SPRINKLER SYSTEM WHEN THE GROSS FLOOR AREA OF THE EXITING BUILDING IS GREATER THAN 5000 SQFT AND THE ALTERATION IS MADE AFFECTING THIRTY PERCENT (30%) OF THE GROSS AREA OF THE BUILDING; THEREFORE THE WHOLE BUILDING SHALL BE PROVIDED WITH AUTOMATIC FIRE SPRINKLER SYSTEM. SUBMIT REVISED PLAN SHOWING THIS REQUIREMENTS.
2. THE PLANS DOES NOT SHOW ANY CODE ANALYSIS ON THE EXISTING CONDITION, SUBMIT TYPE OF CONSTRUCTION, PREVIOUS OCCUPANCY CLASSIFICATION ON EACH LEVEL, TOTAL AREA, FIRE PROTECTION AND ALLOWABLE AREA AND HEIGHT.
3. AISLES WIDTH SHALL BE 48" MINIMUM AND UNIFORM THROUGHOUT THE ENTIRE LENGTH TO ALLOW FOR EXIT TRAVEL IN TWO DIRECTION WITHOUT CREATING A TRAFFIC BOTTLENECK. CONVERGING AISLE SHALL BE NOT LESS THAN 48" MINIMUM WIDTH OR MUST BE CAPABLE OF SERVING THE TOTAL OCCUPANT LOAD SERVED BY THE CONVERGING AISLES. SUBMIT REVISED PLAN SHOWING CORRECT MINIMUM AISLE WIDHT REQUIREMENTS.
4. DRINKING FOUNTAIN SHALL BE A COMBINATION OF HI/LO DRINKING FOUNTAIN.
5. LOBBY AND FELLOWSHIP AREA 111 SHALL BE PROVIDED WITH 2ND MEANS OF EGRESS WHERE THE OCCUPANT LOAD IS MORE THAN 50 PEOPLE. SUBMIT REVISED PLAN.
6. BOTH RESTROOM 205 AND 206 SHALL BE HANDICAP ACCESSIBLE AS PER 2003 IBC 3409.6.
HEALTH AND FOOD SAFETY NOTES;
(4/19/2007 15:03 JS) PENDING. A14 - AREA SUBJECT TO HEALTH AND FOOD SAFETY REVIEW. DEFINE CT1, CT2, CT3; AND DEFINE WHICH IS PROPOSED FOR KITCHEN. DEFINE P1, P2; AND DEFINE WHICH IS PROPOSED FOR KITCHEN. PENDING DETAILS AS TO FINISH HEIGHT ON WALL AND CEILING FINISH.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
PRESTON MANOR
|
APPLICANT | DAVE CARTER | (214)392-3557 | | 1412 ROLLING HILLS | CELINA, TX 75009 |
OWNER | 9741 PRESTON LTD | ()- | | PO BOX 2189 | ADDISON, TX 75001 |
CONTRACTOR | SOUTHWEST SIGNS & GRAPHICS | (000)335-0234 | | 7860 CREEKVIEW RD | FRISCO, TX 75034 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Michele Wood | Appd w/ Conditions | 3/23/2007 | 3/23/2007 | |
More Info
|
COMMERCIAL REVIEW | Pepito P Bunion | Pending | 3/27/2007 | 3/27/2007 | 4/17/2007 |
More Info
|
ELECTRICAL REVIEW | Ginny Queen | Approved | 3/27/2007 | 3/27/2007 | |
More Info
|
MECHNICAL REVIEW | Pepito P Bunion | Approved as Noted | 3/27/2007 | 5/23/2007 | |
More Info
|
HEALTH REVIEW | Julie Stallcup | Denied | 4/17/2007 | 4/18/2007 | 5/8/2007 |
More Info
|
PLUMBING REVIEW | Gilbert Urvina | Approved | 4/25/2007 | 5/24/2007 | |
More Info
|
MISC REVIEW | Michele Wood | N/A | 3/10/2008 | 3/10/2008 | |