Notes:
126 AC, 717 SQ FT, SADD / CABANA-POOL BATH
1/5/2007 12:00:00 AM
1. sheathing inspection req'd.
2. lathe inspection req'd.
3. exhaust fan and supply vent req'd. in bath
4. 2x6 vent walls at plbg. are req'd. at w/c and urinal.
5. 2x8 ceiling joists are overspan at covered porch area, need to install 2x12's and crossblock every 8'.
6. 20 minute rated or solid core doors are req'd. at entry to bath and from bath to covered porch area in lieu of fire sprinkler system.
7. UL U465---1 hr. rated assembly---2 layers of 5/8 type X gypsum board floor to deck at new walls with fire caulking floor to deck where thru wall penetrations occur.
8. all construction methods shall comply with NEC 1999, IRC 2003,
IFC 2003, UL U 465.
9. construction shall be subject to field approval.
10. do not create a mold issue when applying drywall over existing stucco, remove existing stucco before attaching new drywall.