Notes:
1708 SQ FT, CIFO / FUSION CHIROPRACTIC SPA
1/18/2007 12:00:00 AM
PLAN REVIEW COMMENTS;
1. THE NUMBER OF OCCUPANTS COMPUTED AT THE RATE OF ONE OCCUPANT PER UNIT AREAAS PRESCRIBED IN TABLE 1004.1.2 WILL BE (1708 SQFT / 100 SQFT PER OCCUPANT = 17.08 PERSONS) 17 OCCUPANTS.
2. SEPARATE RESTROOM FACILITIES FOR EACH SEX IS REQUIRED IF THE OCCUPANT LOAD IS 15 OR MORE, THEREFORE SUBMIT REVISED FLOOR PLAN SHOWING ADDITIONAL RESTROOM.
3. HI/LO DRINKING FOUNTAIN REQUIRED .
4. DEMISING WALL SHALL BE PROTECTED BY AT LEAST 1-HOUR FIRE RESISTIVE CONSTRUCTION FROM FLOOR TO DECK ABOVE.
5. SAFETY GLAZING REQUIRED FOR WINDOWS 71 AND 78 AT PLAYROOM 103, LIKEWISE STOREFRONT DOOR AND GLAZING SHALL BE SAFETY GLAZING.
6. MEMBRANE PENETRATIONS OF 1-HOUR FIRE RATED DEMISING WALL SHALL BE OF FIRE RESISTIVE MATERIAL AND WITH FIRE STOP SYSTEM.
7. RESTROOM WALL SHALL HAVE A SMOOTH, HARD, AND NON-ABSORBENT SURFACE (PAINTS ARE NOT ALLOWED).
8. CITY OF FRISCO FILING OF CONSTRUCTION DEVELOPMENT DRAWINGS IS ACCEPTED PROVIDED THAT ANY CONTAINED REVISION/UPDATING OR AS-BUILT IS IN STRICT CONFORMANCE WITH THE BASIC PROJECT DESIGN AND CITY'S REVIEW COMMENTS OF ORIGINAL PERMIT SET.