Permit Info
Short Description:
*VOID*3519 AC, 4063 SF, SFR / 2 STORY
Approved Date:
11/16/2006
Notes:
*VOID*3519 AC, 4063 SF, SFR / 2 STORY
11/16/2006 12:00:00 AM
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
10. BEAMS=10"W X 28"D.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
37. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
2nd FLOOR: 3-BED ROOMS, 3-BATHS AND GAME ROOM.
THE DRIVEWAY MUST NOT SLOPE MORE THAN 12% OR 2' 31/2" IN 20'
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
GRIFFIN PARC #01
|
APPLICANT | DISCOVERY SIGNATURE HOMES - X | (940)243-0678 | | 3110 HARTLEE FIELD RD | DENTON, TX 76208 |
OWNER | DISCOVERY SIGNATURE HOMES - X | (940)243-0678 | | 3110 HARTLEE FIELD RD | DENTON, TX 76208 |
CONTRACTOR | DISCOVERY SIGNATURE HOMES - X | (940)243-0678 | | 3110 HARTLEE FIELD RD | DENTON, TX 76208 |
STRUCT ENG | CHILDRESS ENGINEERING X-7/07 | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
ELECT. CTR. | MEGA ELECTRIC CO., INC. X-1 | (972)727-8263 | | P.O. BOX 757 | ALLEN, TX 75013 |
MECH. CTR. | AC ELITE COOLING & HEATING X3/ | (972)270-7790 | | 12640 E. NORTHWEST HWY, STE 40 | DALLAS, TX 75228 |
GEN. CONTR. | DISCOVERY SIGNATURE HOMES - X | (940)243-0678 | | 3110 HARTLEE FIELD RD | DENTON, TX 76208 |
PLUM. CONT. | FRITZ PLUMBING (PLUM) X-1/07 | (972)335-3560 | | P.O. BOX 194 | FRISCO, TX 75034 |
|
RESIDENTIAL ELECTRIC FEE |
$121.89
|
|
MISCELLANOUS MECHANICAL FEES |
$142.50
|
|
MISCELLANEOUS PLUMBING FEES |
$267.00
|
|
BUILDING PERMIT FEE |
$1,808.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $2,360.14
Balance Due: $2,360.14
|
There are currently no inspections on this record.
|
INITIAL REVIEW | MAC | | 11/8/2006 | | 11/29/2006 |
More Info
|
RESIDENTIAL REVIEW | Victor Insko | Appd w/ Conditions | 11/8/2006 | 11/16/2006 | 11/29/2006 |
More Info
|