Notes:
1100 SQ FT, CIFO / FRISCO FLOWERS AND BLOOMS
10/25/2006 12:00:00 AM
PLAN REVIEW COMMENTS;
1. RESTROOM AND DRINKING FOUNTAIN SHALL BE ACCESSIBLE TO THE PUBLIC.
2. WALL FINISH IN THE RESTROOM SHALL BE A HARD, SMOOTH AND NON-ABSORBENT SURFACE, EPOXY PAINT NOT ACCEPTABLE IN CITY OF FRISCO.
3. SPACE SHALL BE HANDICAP ACCESSIBLE.
4. REVISED PLAN HAS BEEN SUBMITTED.
(10/16/2006 14:41 PPB)
PLAN REVIEW COMMENTS.
1. CONNECTION BETWEEN A 1-HOUR FIRE RATED DEMISING WALL AND A STOREFRONT GLASS IS NOT ALLOWED, IT SHOULD BE AT LEAST CONNECTED TO THE MULLION WITH FIRE/SMOKE PROOF PROTECTION. SUBMIT WALL CONNECTION DETAIL THAT COMPLIES.
2. PROVIDE HI/LO DRINKING FOUNTAIN.
3. MOP SINK REQUIRED.
4. ANY WOODS USED IN A TYPE II-B SHALL BE FIRE RATARDANT TREATED WOOD.
5. INTERIOR FINISHES SHALL HAVE AT LEAST FLAME SPREAD RATING OF 76-200 AND SMOKE DEVELOPED OF 0-450.
6. GYPSUM BOARD SHALL BE 5/8" THK TYPE X .
7. BI-LEVEL SWITCHING REQUIRED FOR INTERIOR LIGHTING.