Permit Info
Short Description:
**EXPIRED**2816 AC, 3256 SF, SFR / 2 STORY
Expiration Date:
5/3/2007
Notes:
**EXPIRED**2816 AC, 3256 SF, SFR / 2 STORY
9/1/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
10. BEAMS=10"W X 28"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
30. 1ST FLOOR WINDOW BOX-OUTS MUST HAVE MASONRY BELOW.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
36. REM-RATE REPORT MUST INCLUDE OUTSIDE FRESH AIR REQUIREMENT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
55. FUEL BURNING HOT WATER HEATER INSTALLATION MUST BE CODE COMPLIANT.
(9/1/2006 09:01 PPB)
Special Conditions;
1. Second floor has 1 gameroom, 1 media room, 1bath and 3 bedroom.
2. Power outlet receptacle at stair landing shall be provided.
3. Subject to field inspection.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
GRAYHAWK #04-A
|
APPLICANT | LEGACY HOMES | (972)543-0708 | | 4050 W PARK BLVD | PLANO, TX 75093 |
OWNER | LEGACY HOMES | (972)543-0708 | | 4050 W PARK BLVD | PLANO, TX 75093 |
CONTRACTOR | LEGACY HOMES | (972)543-0708 | | 4050 W PARK BLVD | PLANO, TX 75093 |
HERS PROVIDE | THE NELROD COMPANY (H.E.R.S. P | (817)922-9000 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
STRUCT ENG | CHILDRESS ENGINEERING X-7/07 | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
ELECT. CTR. | IMPERIAL ELECTRIC X-12/2006 | (972)288-7191 | | 50055 PEACHTREE | BALCH SPRINGS, TX 75180 |
MECH. CTR. | AIRTRON INC. x-08/06 | (972)272-9633 | | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
GEN. CONTR. | LEGACY HOMES | (972)543-0708 | | 4050 W PARK BLVD | PLANO, TX 75093 |
PLUM. CONT. | L & S PLUMBING X- 06/2007 | (972)331-6837 | | 8001 ALPHA DR, STE # 109 | RICHARDSON, TX 75081 |
|
RESIDENTIAL ELECTRIC FEE |
$97.68
|
|
MISCELLANOUS MECHANICAL FEES |
$129.50
|
|
MISCELLANEOUS PLUMBING FEES |
$225.00
|
|
BUILDING PERMIT FEE |
$1,548.75
|
|
FENCE FEE |
$20.00
|
|
Total Fees |
Charged: $2,020.93
Balance Due: $2,020.93
|
There are currently no inspections on this record.
|
INITIAL REVIEW | MAC | | 8/22/2006 | | 9/12/2006 |
More Info
|
RESIDENTIAL REVIEW | PPB | Approved as | 8/22/2006 | 9/1/2006 | 9/12/2006 |
More Info
|