Permit Info
Short Description:
19030 SQ FT, CNEW / TIMBER RIDGE RETAIL (SHELL)SEE B08-1570
Expiration Date:
3/10/2008
Notes:
1- CONTINGENT UPON P+Z & CIVIL ENGG APPROVALS OF FINAL SITE PLAN, COMPLIANCE TO BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- PENDING SUBMITTAL OF DUMPSTER ENCLOSURES CONSTRUCTION DETAILS (ARCH'L & STRUCT'L) AS PER CITY CRITERIA, INCLUDING REQ'D ADDITIONAL FACILITY. SYSTEM MUST BE OK'D BY THE ENVIRONM'L SVCS DEPT. (972-292-5900) & APPROVED BEFORE STARTING ANY CONSTRUCTION.
3- BLDG PERMITTED FOR MIXED USE OF 1ST FLR RETAIL (M) & 2ND FLR MEDICAL OFFICES (B) WITH MIN. 79 PARKING SPACES FOR TOTAL BLDG.
4- PROVISION OF FULL BLDG ENVELOPE INSULATION IS PART OF THIS SHELL PERMIT. MIN. R-25 ROOF OR ATTIC INSULATION IS REQ'D BETWEEN METAL FRMG.
5- MECH'L ATTIC TO BE SEPARATED FROM 2ND FLR TENANTS BY DOUBLE LAYER 5/8" TYPE 'X' GYP BD UNDER THE BOTTOM CHORD OF ROOF TRUSSES. PROVIDE F.R.T. PLYW'D MECH'L DECKING ON MTL FRMG AS PER ENGR'S DTLS AND 1 HR RATED ATTIC HATCH AT THE TOP OF EACH STAIRWELL AS REQ'D.
6- STRUCT'L ENGR OF RECORD TO BE RESPONSIBLE FOR THE DESIGN AND COORDINATION OF ALL STRUCT'L PARTS IN THIS PROJECT, INCLUDING ANY STRUCT'L ELEMENTS DESIGNED BY OTHERS. DESIGN MUST BE SUITABLE FOR WIND EXPOSURE 'C' AS REQ'D. 2ND FLR SLAB CONC. TO BE 3-1/2" ON TOP OF METAL DECK FOR 1 HR EQUIVALENT THICKNESS WHEN USING NORMAL WEIGHT CONC. [SEC. 720.1(3) IBC].
7- 2ND FLR STOREFRONT ALONG EXIT BALCONY TO BE TOPPED BY 1 HR FIRE/SMOKE BULKHEAD UP TO UNDERSIDE OF ROOF DECK. ALL 2ND FLR GLAZING TO BE SPRINKLER PROTECTED TEMPERED GLASS AS REQ'D.
8- ELEVATOR MACHINE ROOM TO BE 1 HR RATED AND LOCATED TO BE COMMOMLY ACCESSED AS REQ'D. ELEV. MACH. RM DOOR & ALL STAIR DOORS TO BE 1 HR RATED IN 1 HR FRAME.
9- MECH'L ITEMS ON ROOF ARE NOT ALLOWED. ATTIC VENTILATION TO BE VIA LOUVERED END GABLES OR DORMERS OR OTHER SIMILAR ARCHIT'L FEATURES. ROOF GUTTERS TO BE SIZED FOR MIN. 6"/HR RAINFALL AND ALL DOWNSPOUTS TO BE DIRECTLY CONNECTED TO UNDERGROUND STORM SYSTEM.
10- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
19030 SQ FT, CNEW / TIMBER RIDGE RETAIL (SHELL)SEE B08-0474
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
Huffman FM 720 Addn
|
APPLICANT | Huffman Builders LP | (972)248-1667 | jhuffman@huffmancommercial.com | 1320 Village Creek Drive, # 13 | FRISCO, TX 75034 |
OWNER | Huffman Builders LP | (972)248-1667 | jhuffman@huffmancommercial.com | 1320 Village Creek Drive, # 13 | FRISCO, TX 75034 |
CONTRACTOR | HUFFMAN BUILDERS, LLC | (972)248-1667 | | 5300 W PLANO PKWY # 100 | PLANO, TX 75093 |
GEN. CONTR. | HUFFMAN BUILDERS, LLC | (972)248-1667 | | 5300 W PLANO PKWY # 100 | PLANO, TX 75093 |
OTHER | Winstead Sechrest & Minick | (214)745-5746 | | 5400 Renaissance Tower | Dallas, TX 75270 |
|
THOROUGHFARE IMPACT FEE |
$187,532.00
|
|
WATER IMPACT FEE |
$47,775.00
|
|
SEWER IMPACT FEE |
$15,534.00
|
|
MISCELLANEOUS ELECTRICAL FEES |
$520.60
|
|
MISCELLANOUS MECHANICAL FEES |
$97.00
|
|
MISCELLANEOUS PLUMBING FEES |
$77.00
|
|
COMMERCIAL BUILDING PERMIT FEE |
$3,365.25
|
|
Total Fees |
Charged: $254,900.85
Balance Due: $254,900.85
|
There are currently no inspections on this record.
|
COMMERCIAL REVIEW | UA | Comply as Co | 8/9/2006 | 8/21/2006 | |
More Info
|
ELECTRICAL REVIEW | JM | Appd w/ Cond | 8/9/2006 | 9/14/2006 | |
More Info
|
HEALTH REVIEW | JRS | Not Required | 8/9/2006 | 8/23/2006 | |
More Info
|
INITIAL REVIEW | MBW | Pending | 8/9/2006 | 8/9/2006 | |
More Info
|
MECHNICAL REVIEW | TW | | 8/9/2006 | 8/24/2006 | |
More Info
|
PLUMBING REVIEW | GU | Approved | 8/9/2006 | 9/5/2006 | |
More Info
|
MISC REVIEW | Michele Wood | N/A | 3/10/2008 | 3/11/2008 | |
More Info
|