Notes:
1- CONTINGENT UPON P+Z & CIVIL ENGG APPROVALS OF FINAL SITE PLAN, COMPLIANCE TO BLDG CODE & CITY REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- CONFORM TO CITY CRITERIA DETAILS FOR LOCATION AND QUANTITY OF DUMPSTER ENCLOSURES. SYSTEM MUST BE O.K'D BY THE ENVIRONM'L SVCS DEPT PRIOR STARTING ANY CONSTR'N.
3- BLDG MUST BE COMPLETELY HC ACCESSIBLE AND NO STEPS SHALL BE ALLOWED FROM HC PKG TO BLDG ENTRANCES.
4- PROVIDE 42" HIGH GUARDRAILS WHERE WALKING SURFACES ALONG PORCHES, RETAINING WALLS, RAMPS, ETC., ARE MORE THAN 30" ABOVE THE GRADE BELOW. RAMPS SLOPING MORE THAN 5% OR 1:20 RATIO (1:12 MAX.ALLOWED) MUST BE PROVIDED WITH HANDRAILING ON BOTH SIDES AS REQ'D.
5- ALL STRUCT'L DESIGNS PERTAINING THE ENTIRE PROJECT (FNDS, BLDG STRUCTURE, RETAINING WALLS, DUMPSTER WALLS, ETC.) TO BE UNDER THE PROFESSIONAL COORDINATION OF THE RESPONSIBILE STRUCT'L ENGR OF RECORD, INCLUDING STRUCT'L WORKS DESIGNED BY OTHERS.
6-1 HR FIRE RATED OXIGEN CLOSED TO HAVE 1 HR DOOR AND BE VENTED TO OUTSIDE AS PER NFPA REGULATIONS. SERVER ROON #112 TO HAVE 1 HR WALLS, 1 HR CLG & MIN. 45 MINUTE RATED DOOR IN 1 HR FRAME. SEPARATE LOBBY AREA WITH 1 HR WALLS & PROTECTED OPENINGS AS REQ'D.
7- PROVIDE HI/LO (DUAL LEVEL OR DOUBLE) DRINKING FOUNTAIN AS PER TAS. LOCATION MAY BE AS SUGGESTED BY THE REVIEW MARKS OR OPTIONAL, SUBJECT TO APPROVAL.
8- FOLDING CLG STAIRS FOR ATTIC ACCESS IS NOT ALLOWED UNLESS MADE OF MIN. 30"X 54" METAL UNIT, MIN. 500 lbs FACTORY-LABELED CAPACITY AND WITH PROPERLY INSULATED CLG PANEL. TECHNICAL INFO MUST BE SUBMITTED WITH STRUCT'L ENGR'S DTLS OF THE CLG FRAMING NEEDED FOR THE STAIR UNIT'S INSTALLATION.
9- MECH'L EXHAUSTS TO BE THRU PAINTED WALL LOUVERS AS MUCH AS POSSIBLE WITH ONLY SMALL INCONSPICUOUS VENTS OR FLUES ON ROOF WHEN UNAVOIDABLE, SPECIFICALLY PERMITTED BY INSPECTORS, AND PAINTED TO MATCH COLOR OF ADJACENT MATERIALS. (USE VEGETATION TO MASK ANY MECH'L EQUIP. ON GROUND).
10- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
5365 SQ FT, CNEW / LAZY PAW ANIMAL HOSPITAL