Notes:
1260 SQ FT, CIFO / AT HOME DINNERS
12/2/2005 12:00:00 AM
1. 1 hour fire/smoke connection to mullion.
2. 1 hour fire/smoke construction w/ 6” metal studs w/ 5/8” type X gypsum on both sides up to deck, fire caulk floor to deck.
3. tempered windows and doors at front.
4. class 1 hood, with 2 shaft enclosure or app'd. fire wrap.
5. door must open out for ada compliant unisex restroom, additional restroom shall be employee's restroom, door may open in and no change is req'd.
(12/14/2005 10:41 JRS) (
P. 1 - MUST COMPLY WITH CITY OF FRISCO HEALTH ORDINANCE #00-03-19 AND SMOKING ORDINANCE #00-12-12. ALL EQUIPMENT SHALL BE ANSI-SANITATION APPROVED AND APPROVED FOR INTENDED USE. SOAP AND TOWEL DISPENSERS SHALL BE MOUNTED. COVED TILE BASE INTEGRAL WITH FLOOR REQUIRED IN KITCHEN, RESTROOM, AND "WORK AREA". (A) "WORK AREA" - WALLS IN "WORK AREA" SHALL BE DURABLE AND EASILY CLEANABLE TO 5 FT. - FRP TYPICAL. (B) RESTROOMS - RESTROOM WALLS SHALL BE DURABLE AND EASILY CLEANABLE TO WAINSCOTT. RESTROOM FLOORS SHALL BE DURABLE AND EASILY CLEANABLE WITH INTEGRAL COVED TILE BASE. EMPLOYEE HANDWASH SIGNAGE REQUIRED. (C) KITCHEN - KITCHEN WALLS TO BE FLOOR TO CEILING DURABLE AND EASILY CLEANABLE. FRP TYPICAL. (D) PREP SINK - SPLASH GUARD REQUIRED - 8 INCH VERTICAL MINIMUM - DURABLE AND EASILY CLEANABLE - STAINLESS STEEL TYPICAL. P. 2 - ALL LIGHTING IN FOOD AREAS MUST BE TEMPERED, SHATTERPROOF, OR COVERED. LIGHTING MUST MEET REQUIREMENTS OF HEALTH ORDINANCE. MUST POST SMOKING SIGNAGE IN COMPLIANCE WITH CITY OF FRISCO ORDINACE #00-12-12. SEE ATTACHED SHEET. P.3 - WATER HEATER SHALL BE EQUAL TO OR GREATER THAN 15.4 KW (74970 BTU) WITH RECOVERY RATE OF 72 GPH OR GREATER. P. 4 - TEST PORT REQUIRED AT GREASE INTERCEPTOR. MOP SINK SHALL DISCHARGE TO GREASE INTERCEPTOR.