Notes:
1- CONTINGENT UPON P+Z & CIVIL ENGG APPROVALS OF FINAL SITE PLAN, COMPLIANCE TO BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- DUMPSTER ENCLOSURE TO BE APPROVED BY THE ENVIRONM'L SVCS DEPT (972-335-5519) PRIOR STARTING ANY CONSTRUCTION.
3- ALL STRUCTURAL ISSUES RELATED TO THIS ENTIRE PROJECT, INCLUDING METAL BLDG, ROOF FRAMING, ETC., SHALL BE FULLY COORDINATED UNDER THE PROFESSIONAL RESPONSIBILITY OF THE STRUCT'L ENGR OF RECORD (INCLUDING STRUCTURAL WORKS DESIGNED BY OTHERS). ENGR TO SIZE METAL ROOF PANELS UNLESS APPLIED OVER STRUCT'LLY SPECIFIED DECKING IN CONFORMANCE TO SEC. 1507.4 IBC.
4- ARCH. TO SUBMIT MANUF. INFORMATION ON STAND-UP MTL SEAMS ROOFING CLARIFYING IF ANY UNDERLAYMENT IS NECESSARY OR NOT AND PROVIDE ALL DETAILS ON FLASHING CONN. @ PARAPETS, ROOF HATCH, MECH'L EQUIP., ETC.
5- NO ROOF-TOP MECH'L EQUIPMENT ALLOWED UNLESS CONCEALED FROM PUBLIC VIEW BY PARAPET OR OTHER APPROVED ARCHITECT'LLY DESIGNED SCREENING.
6- TOILETS TO BE REVISED AS REQUIRED FOR ADA/TAS COMPLIANCE.
7- HAZARDOUS MATERIALS MUST BE SPECIFIED. HAZMAT STORAGE AREA SUBJECT TO FIRE MARSHAL'S REQUIREMENTS AND SPECIFIC APPROVALS. PROVIDE PROTECTED OPENINGS AND FIRE/SMOKE COMBINATION DAMPERS AT ALL DUCTS PENETRATIONS OF RATED WALLS AS REQ'D.
8- SHELL AREAS ARE SEPARATE SUITES AND MAY NOT BE OCCUPIED UNTIL COMPLETED FINISH-OUT PLANS ARE SUBMITTED AND APPROVED UNDER SEPARATE PERMIT APPLICATIONS. (PREPARATION FOR DIRECT EXIT DOOR FROM WAREHOUSE SPACE IS RECOMMENDED).
9- UPDATED PLANS ACCORDING TO REVIEW COMMENTS TO BE RESUBMITTED WITH CLOUDED/DATED REVISIONS FOR VERIFICATION & FINAL RECORDS.
10- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL & FIELD INSPECTIONS.
30000 SQ FT, CNEW / SCP FACILITY