Notes:
1- CONTINGENT UPON COMPLIANCE WITH BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- NO PLUMBING IS ALLOWED INSIDE COMPLETED FIRE RATED DEMISING WALL (BASED ON UL DESIGN U465). ANY FLANKING PLBG MUST BE IN ADDED CHASE.
3- DEMISING WALL ENDING @ STOREFRONT MUST HAVE VALID 1 HR FIRE/SMOKE CONNECTION TO WALL OR MULLION (JAG WALL IF NECESSARY). SUBMIT ENTIRE STOREFRONT WITH SAFETY GLASS AS REQ'D AND WITH ALL PERTINENT DETAILS, INCLUDING NEW SLIDING DOOR INFO., FOR APPROVAL.
4- DRINKING FOUNTAIN TO BE DUAL HI/LO SYSTEM OR ONE OF STANDARD HEIGHT PLUS ONE BOTTLED WATER COOLER WITH CUP DISPENSER.
5- POST SIGN FOR TOTAL ALLOWED OCCUPANCY LOAD OF 15 PEOPLE (CUSTOMERS PLUS EMPLOYEES), UNLESS A SECOND TOILET FACILITY IS ADDED AS REQ'D.
6- SUBJECT TO TDLR & M.E.P. REVIEWS, SPECIFIC DRY CLEANING EQUIPMENT & CODE COMPLIANCE DOCUMENTATION, FIRE MARSHAL AND FIELD INSPECTIONS.
1668 SQ FT, CIFO / ELY CLEANERS