Notes:
2094 AC, 3186 SQ FT, SFR / 2 STORY
12/8/2003 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
11. BEAMS=10"W X 29"D.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
40. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
42. PROVIDE SOIL MOISTURE TREATMENT DOCUMENTATION PRIOR TO STARTING CONSTRUCTION.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
2nd FLOOR WITH HALF BATH & GAME ROOM.
ENGINEER OF RECORD SEAL REQ"D NOT STAMP ONLY ON FRAMING DRW'GS. FUTURE SUBMITTALS WILL BE REJECTED.
(5/5/2004 16:46 JLS) CO INSPECTION ON 5/3/04 APPROVED PER KEN HUSTON. SYSTEM WOULD NOT ALLOW ENTRY.