Notes:
1- CONTINGENT UPON COMPLIANCE WITH ALL CODE REQUIREMENTS, PERTINENT LEGISLATIONS AND ALL CITY COMMENTS.
2- PENDING SUBMITTAL OF ASBESTOS DOCUMENTATION ON EXISTING AND NEW CONSTRUCTION IN CONFORMANCE TO SB 509 AND HB 1927.
3- PENDING UPDATE FILING OF STRUCTURAL REVISIONS CONTAINING ALL STRUCTURAL CHANGES FROM SHELL PERMIT B02-1881 INCLUDING RELOCATION OF STAIRS AND REVISED TILT-UP PANEL OPNGS AT ADDED SHIPPING DOCK.
4- THE BLDG'S MULTI-TENANT ORIGINAL CONCEPT OF 1 HR PROTECTED EXIT CORRIDOR CONNECTING TWO MEANS OF EGRESS (SHELL PERMIT B02-1881) IS TO BE MAINTAINED AS MUCH AS POSSIBLE AND ADJUSTED INTO THE NEW SINGLE-TENANT FINISH-OUT DESIGN, AS REQ,D.
5- THE FINISH-OUT DESIGN OCCUPANCY FOR THE 2ND FLOOR NORTH WING IS EXCEEDING 500 PEOPLE (REQUIRING A THIRD MEANS OF EGRESS). THEREFORE, A 2 HR SEPARATION WALL, WITH AN HORIZONTAL EXIT (WHICH ALLOWS EXITING FROM EACH SIDE), IS REQUIRED TO SUB-DIVIDE THE SPACE IN TWO AND HAVING THE WALL SUPPORTING STRUCTURE FIREPROOFED WITH AN APPROVED 2 HR RATED ASSEMBLY PROTECTION SYSTEM, AS PER COMMENTS.
6- ADD TOILET AND DRINK'G FOUNTAIN FACILITIES ON 1ST & 2ND FLRS OF NORTH BLDG WING AS REQ'D.
7- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
115800 SQ FT, CIFO / EADS TELECOM