Notes:
2277 AC, 2884 SQ FT, DPLX / 2 STORY
4/9/2003 12:00:00 AM
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
BEAMS 10"X36"
23. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
32. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
35. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
45. SEE SOUND TRANSMISSION CODE COMPLIANCE DATA SHEET ATTACHED.
46. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
64. ATTIC VENTILATION PER IRC R.806.2.
67. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC
(2/3/2004 10:07 DEB) REINSTATED THE STATUS TO ISSUED PER SLC