Notes:
2045 AC, 452 SQ FT, DPLX / 2 STORY
2/22/2003 12:00:00 AM
38. ENERGY STAR SUMMARY REPORT A.C. AREA MUST BE WITHIN 1% OF PERMIT / PLAN A.C. AREA.
(03/09/2003 12:56 JC)
1. ***ENERGY STAR***
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
10.BEAMS=10"W X 28"D.
45. SEE SOUND TRANSMISSION CODE COMPLIANCE DATA SHEET ATTACHED.
46. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
52. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING.
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
64. ATTIC VENTILATION PER IRC R.806.2.
(03/09/2003 12:56 JC)2nd. floor w/ (2) B.R.'s, (1) bath, game room and utility rm. Consider waterproofing utility rm. floor and adding a floor drain