Notes:
3198 AC, 4139 SQ FT, SFR / 2 STORY
2/10/2003 12:00:00 AM
story at J-garage(03/05/2003 15:47 JC)
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
5. BEAMS=8"W X 28"D.
23. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
36. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
46. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
48. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. STRUCTURAL COL'S MUST BE A MIN. OF 4" X 4" WOOD (OR) 3" O.D. STEEL
54. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
64. ATTIC VENTILATION PER IRC R.806.2.
67. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(03/05/2003 15:47 JC)2nd. floor w/ (2) B.R.'s, (1) bath , game rm. & bonus rm.