Notes:
5516 AC 7457 SQ FT, SFR / 2 STORY
11/17/2002 12:00:00 AM
1. ***ENERGY STAR***
2. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
3. BEAMS=8"W X 24"D.
23. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
27. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
47. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
53. CSST GAS PIPING PROHIBITED IN FRISCO.
63. RECESSED LIGHT FIXTURES MUST BE 2000 IECC CODE COMPLIANT.
66. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(11/17/2002 10:23 JC)Correct set-back at front yard to 25' from 20'. Attic storage with flooring and lighting must be fully sprinklered with freeze protection if un-heated. 2nd. floor w/ (2) B.R.'s, (1) bath and game room in AC area.
(11/18/2002 13:50 JC)Permit being held subject to further review of the foundation design.