Print Inspection Report

Date Time
11/15/2025
6:33 PM

 
Permit Details
Permit No. B24-03390 Permit Type   BUILDING Site Address   11328 FINCH HATTONS DR
FRISCO
Applied   09/06/2024 Applicant   Monique Mendoza
Approved   09/24/2024 Owner   LLC BR637
Issued   09/24/2024 Contractor   LANDON HOMES
Parent Permit No.   Description   3673 AC, 4274 SF, 2 STORY
  Notes  
 
Date of Inspection Inspection Type Inspector Result Remarks Notes

Heading 09/24/2024METER PAYMENTAPPROVED

Heading 10/09/2024T-POLE RESPAUL FONTENOTAPPROVEDeTRAKiT Inspection Request10/8/2024 3:44:20 PM 10/8/2024 3:44 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com

Heading 10/11/2024SET 1 PD METERCARLOS D RODRIGUEZAPPROVED10/11/2024 8:47:58 AM SET 1 INCH METER

Heading 10/15/2024PLUMBING ROUGH-INSTEVEN HEAD I-3598APPROVEDKD in the back10/14/2024 4:16:06 PM 10/14/2024 4:16 PM LANDON HOMES Contact Name: Christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com

Heading 10/18/2024SLAB RESPAUL FONTENOTAPPROVEDeTRAKiT Inspection Request10/17/2024 3:44:27 PM 10/17/2024 3:44 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com

Heading 11/07/2024PTO AND MECH ROUGHSTEVEN HEAD I-3598RES FAILEDDV third on the left sidewall11/6/2024 12:05:27 PM 11/6/2024 12:05 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com 11/7/2024 10:58:03 AM No gas test, no PVC water test, left side second floor tub overflow, leaking to the first floor. Attic decking installed in dangerous manner with cantilever edges and overcut plywood. Dedicated 24-inch walkway from the last step of the ladder to the furnace decking incomplete. Furnace and coil decking platform obstructed by roof braces.

Heading 11/12/2024PTO AND MECH ROUGHSTEVEN HEAD I-3598RES FAILEDeTRAKiT Inspection Request11/11/2024 4:04:19 PM 11/11/2024 4:04 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com 11/12/2024 9:21:07 AM 1. Gas test low, well below the minimum 3 psig. 2. PVC water test very low in the test pipe on the second floor. 3. The tub that was leaking at the last inspection is not on test for this inspection and the drain has been completely remove and a test ball installed. The test ball must be removed, tub drain assembled and plugged for test as we will never see the drain hold again once covered with sheetrock and finished surfaces. 4. The attic decking overcuts must be reenforced to remain as installed. The 24-inch walkway to the furnace platform must be continuous without gaps in the decking. There will be a 72 hour hold assessed at the next disapproval.

Heading 11/13/2024PTO AND MECH ROUGHSTEVEN HEAD I-3598APPROVEDeTRAKiT Inspection Request11/12/2024 4:22:37 PM 11/12/2024 4:22 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com

Heading 11/14/20242NDS AND FRAMINGPAUL FONTENOTRES FAILEDeTRAKiT Inspection Request11/13/2024 1:10:11 PM 11/13/2024 1:10 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com 11/14/2024 10:23:39 AM 1. Missing fasteners at SUR410 angled hanger for 2ply i-joists over dining. 2. Drain tubs and showers. 3. Fix failing flashing at sheathing seam left side 2nd floor. 4. Kitchen nook sheathing needs to have double portal frame nailing pattern, missing grid at each side of header.

Heading 11/15/20242NDS AND FRAMINGPAUL FONTENOTAPPROVEDeTRAKiT Inspection Request11/14/2024 5:06:12 PM 11/14/2024 5:06 PM LANDON HOMES Contact Name: Christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com

Heading 11/20/2024INSULATION RESPAUL FONTENOTAPPROVEDeTRAKiT Inspection Request11/19/2024 12:40:54 PM 11/19/2024 12:40 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com

Heading 11/20/2024BRICKWALL TIES RESPAUL FONTENOTAPPROVEDeTRAKiT Inspection Request11/19/2024 12:40:54 PM 11/19/2024 12:40 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com

Heading 11/22/2024DRYWALL RESPAUL FONTENOTAPPROVEDeTRAKiT Inspection Request11/21/2024 10:18:00 AM 11/21/2024 10:17 AM LANDON HOMES Contact Name: Christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com

Heading 12/09/2024FLATWORK RESROBERT TSADICANCELLEDeTRAKiT Inspection Request12/6/2024 3:12:28 PM 12/6/2024 3:12 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com 12/9/2024 10:32:19 AM Workers draining water from approach

Heading 12/10/2024FLATWORK RESROBERT TSADIAPPROVEDeTRAKiT Inspection Request12/9/2024 11:51:49 AM 12/9/2024 11:51 AM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2142085506 e-Mail: ckaehn@landonhomes.com

Heading 01/06/2025GAS RELEASEJEREMY WRIGHT I-3318RES FAILEDeTRAKiT Inspection Request1/3/2025 5:05:32 PM 1/3/2025 5:05 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2146191070 e-Mail: ckaehn@landonhomes.com 1/6/2025 9:40:15 AM no test on gas, gas has been reworked in kitchen, a full gas test will be required

Heading 01/07/2025ELECT FINAL RESROBERT TSADIAPPROVEDeTRAKiT Inspection Request1/6/2025 10:40:30 AM 1/6/2025 10:40 AM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2146191070 e-Mail: ckaehn@landonhomes.com

Heading 01/08/2025GAS RELEASEJEREMY WRIGHT I-3318APPROVEDeTRAKiT Inspection Request1/7/2025 9:32:19 AM 1/7/2025 9:32 AM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2146191070 e-Mail: ckaehn@landonhomes.com

Heading 01/21/2025UTILITIES INSPECTIONTHOMAS LEALAPPROVEDeTRAKiT Inspection Request1/16/2025 2:56:26 PM 1/16/2025 2:56 PM LANDON HOMES Contact Name: LANDON HOMES Site Address: 11328 FINCH HATTONS DR Phone: 2146191070 e-Mail: ckaehn@landonhomes.com

Heading 01/28/2025PLUMB MECH FINALJEREMY WRIGHT I-3318APPROVEDeTRAKiT Inspection Request1/27/2025 1:56:18 PM 1/27/2025 1:56 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2146191070 e-Mail: ckaehn@landonhomes.com

Heading 01/30/2025CO AND BUILD FINALROBERT TSADIRES FAILEDeTRAKiT Inspection Request1/29/2025 3:53:59 PM 1/29/2025 3:53 PM LANDON HOMES Contact Name: christian kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2146191070 e-Mail: ckaehn@landonhomes.com 1/30/2025 3:26:36 PM 1. Missing weather stripping throughout 2. Silicone expansion joints in brick 3. Silicone around all penetrations through brick 4. Clean out garbage disposal

Heading 02/06/2025CO AND BUILD FINALJEFF ELLIS I-3380APPROVEDeTRAKiT Inspection Request2/5/2025 3:12:07 PM 2/5/2025 3:12 PM LANDON HOMES Contact Name: Christian Kaehn Site Address: 11328 FINCH HATTONS DR Phone: 2146191070 e-Mail: ckaehn@landonhomes.com