Print Inspection Report

Date Time
11/15/2025
7:24 PM

 
Permit Details
Permit No. B23-02642 Permit Type   BUILDING Site Address   9715 SPEAKER DR
FRISCO, TX 75035
Applied   06/29/2023 Applicant   CB Jeni Homes
Approved   07/17/2023 Owner   CB JENI 2020 LLC
Issued   07/17/2023 Contractor   CB JENI 2020 LLC
Parent Permit No.   Description   1900 AC, 2496 SF, 2 STORY
  Notes  
 
Date of Inspection Inspection Type Inspector Result Remarks Notes

Heading 07/21/2023METER PAYMENTKASSANDRA ARGUELLO GUZMANAPPROVEDREADY

Heading 07/24/2023SET 1 PD METERHANK JOHNSONAPPROVED7/24/2023 2:23:03 PM SET 1 INCH METER

Heading 07/27/2023T-POLE RESROBERT TSADIAPPROVEDeTRAKiT Inspection Request7/26/2023 9:13:57 AM 7/26/2023 9:13 AM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@normandyhomes.com

Heading 07/28/2023PLUMBING ROUGH-INJEFF ELLIS I-3380APPROVEDk.d. left side.7/27/2023 2:03:09 PM 7/27/2023 2:03 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@normandyhomes.com

Heading 08/04/2023SLAB RESROBERT TSADICANCELLEDeTRAKiT Inspection Request8/3/2023 10:40:32 PM 8/3/2023 10:40 PM CB JENI 2020 LLC MODEL can you please do an afternoon inspection. I know it is Friday and I am sorry for this request. Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@normandyhomes.com 8/4/2023 9:19:23 AM Per Builder

Heading 08/07/2023SLAB RESDANIEL WHORNHAMRES FAILEDeTRAKiT Inspection Request8/6/2023 7:51:21 PM 8/6/2023 7:51 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@normandyhomes.com 8/7/2023 10:38:02 AM 1) Need 1" clear between all vertical pipes, conduit, and foam wrapped flex lies. 2) Provide String lines for slab area to measure beam depth. 3) Need 3/4" clear at all cable dead ends. 4) All diagonal reinforcing needs to be at least mid-depth of slab. 5) Need Chairs per G/S3 at recessed slab areas. 6) Need reinforcing per G-2 at mid-walls. 7) Need 2" minimum between Ufer and cables. 8) Need chairs under, over, and to the side of all plumbing.

Heading 08/08/2023SLAB RESDALTON FALLAWAPPROVEDeTRAKiT Inspection Request8/7/2023 5:11:19 PM 8/7/2023 5:11 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@normandyhomes.com

Heading 08/24/2023FIRE RATED WALL RESPAUL FONTENOTAPPROVEDeTRAKiT Inspection Request8/23/2023 4:24:14 PM 8/23/2023 4:24 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@normandyhomes.com

Heading 08/31/2023SHEATHING RESROBERT TSADIAPPROVEDeTRAKiT Inspection Request8/30/2023 2:34:18 PM 8/30/2023 2:34 PM CB JENI 2020 LLC Contact Name: CB JENI 2020 LLC Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 09/08/2023PTO AND MECH ROUGHDEWAYNE CARTER I-3400RES FAILEDeTRAKiT Inspection Request9/7/2023 3:08:50 PM 9/7/2023 3:08 PM CB JENI 2020 LLC Contact Name: CB JENI 2020 LLC Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com 9/8/2023 9:39:06 AM Missing flashing, insulate water line, drain wrong side of loop vent, fresh air 10ft from exhaust

Heading 09/12/2023BRICKWALL TIES RESROBERT TSADICANCELLEDeTRAKiT Inspection Request9/11/2023 9:39:14 AM 9/11/2023 9:39 AM CB JENI 2020 LLC Contact Name: CB JENI 2020 LLC Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com 9/12/2023 8:48:20 AM Not Ready

Heading 09/13/2023PTO AND MECH ROUGHSTEVEN HEAD I-3598APPROVEDdv only one on rear roof9/12/2023 3:20:53 PM 9/12/2023 3:20 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 09/14/20232NDS AND FRAMINGROBERT TSADICANCELLEDeTRAKiT Inspection Request9/13/2023 1:30:26 PM 9/13/2023 1:30 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com 9/14/2023 3:19:11 PM Must pass fire suppression inspection

Heading 09/18/2023BRICKWALL TIES RESROBERT TSADIAPPROVEDeTRAKiT Inspection Request9/18/2023 6:40:12 AM 9/18/2023 6:40 AM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 09/18/20232NDS AND FRAMINGROBERT TSADIRES FAILEDeTRAKiT Inspection Request9/15/2023 1:53:00 PM 9/15/2023 1:53 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com 9/18/2023 9:51:02 AM 1. Pass fire suppression inspection 2. 5 side fire block gas shutoff valve box on firewall in kitchen 3. Poly all subfloor penetrations 4. Seal all fire blocking at change in elevations 5. Seal top of all chases OK to brick and install siding

Heading 09/22/20232NDS AND FRAMINGROBERT TSADIRES FAILEDeTRAKiT Inspection Request9/21/2023 3:18:00 PM 9/21/2023 3:17 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com 9/22/2023 3:21:34 PM 1. Pass fire suppression inspection OK to foam insulate roof decking

Heading 09/28/20232NDS AND FRAMINGROBERT TSADIAPPROVEDeTRAKiT Inspection Request9/27/2023 3:58:51 PM 9/27/2023 3:58 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 10/04/2023FLATWORK RESROBERT TSADIAPPROVEDeTRAKiT Inspection Request10/3/2023 3:58:11 PM 10/3/2023 3:58 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 10/05/2023INSULATION RESROBERT TSADIAPPROVEDeTRAKiT Inspection Request10/4/2023 3:24:05 PM 10/4/2023 3:24 PM CB JENI 2020 LLC Contact Name: Clark Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 10/10/2023DRYWALL RESROBERT TSADIAPPROVEDeTRAKiT Inspection Request10/9/2023 12:45:59 PM 10/9/2023 12:45 PM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 11/07/2023UTILITIES INSPECTIONTHOMAS LEALAPPROVEDeTRAKiT Inspection Request11/3/2023 10:15:55 AM 11/3/2023 10:15 AM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 11/13/2023ELECT FINAL RESROBERT TSADIRES FAILEDeTRAKiT Inspection Request11/12/2023 10:10:02 PM 11/12/2023 10:10 PM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com 11/13/2023 3:17:09 PM 1. Missing no lox grease at meter base 2. Missing 2nd set screw at main disconnect 3. AC breaker is oversized

Heading 11/15/2023GAS RELEASEMIKE MCDONALD I-3343APPROVEDeTRAKiT Inspection Request11/14/2023 8:56:22 PM 11/14/2023 8:56 PM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 11/16/2023ELECT FINAL RESROBERT TSADIAPPROVEDeTRAKiT Inspection Request11/16/2023 6:31:42 AM 11/16/2023 6:31 AM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 12/14/2023PLUMB MECH FINALJEFFREY RODRIGUEZ I-4143RES FAILEDeTRAKiT Inspection Request12/13/2023 3:24:33 PM 12/13/2023 3:24 PM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com 12/14/2023 11:11:56 AM 1) Dryer vent termination must be single flap unscreened 2) AC duct separated at splice in attic 3) Water heater exhaust is missing required fasteners

Heading 12/19/2023PLUMB MECH FINALDEWAYNE CARTER I-3400APPROVEDeTRAKiT Inspection Request12/18/2023 2:23:20 PM 12/18/2023 2:23 PM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com

Heading 12/20/2023CO AND BUILD FINALPAUL FONTENOTRES FAILEDeTRAKiT Inspection Request12/19/2023 2:26:13 PM 12/19/2023 2:26 PM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com 12/20/2023 1:27:05 PM Garage door should be self closing.

Heading 12/21/2023CO AND BUILD FINALGINNY QUEENCANCELLEDeTRAKiT Inspection Request12/20/2023 3:16:42 PM 12/20/2023 3:16 PM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com 12/21/2023 8:30:55 AM Fox Electric State license has expired 7/31/23 registration expired Insurance expired 7/31/23

Heading 12/22/2023CO AND BUILD FINALGINNY QUEENAPPROVEDeTRAKiT Inspection Request12/21/2023 2:19:35 PM 12/21/2023 2:19 PM CB JENI 2020 LLC Contact Name: Clark L Williams Site Address: 9715 SPEAKER DR Phone: 4693286085 e-Mail: cwilliams@cbjenihomes.com