Date of Inspection Inspection Type Inspector Result Remarks Notes

Heading 05/02/2022METER PAYMENTMAYRA BENITEZAPPROVED

Heading 06/02/2022SET 1 PD METERJOSE RUIZ-CASTELLONAPPROVED6/2/2022 8:57:07 AM SET 1 INCH METER

Heading 06/02/2022T-POLE RESPAUL FONTENOTAPPROVEDeTRAKiT Inspection Request6/2/2022 6:49:55 AM 6/2/2022 6:49 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 06/13/2022PLUMBING ROUGH-INSTEVEN HEAD I-3598RES FAILEDkd in the back6/13/2022 6:29:47 AM 6/13/2022 6:29 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 6/13/2022 10:03:57 AM No PVC water test, Cleanup all site trash and joining lot trash. Trash bin overflowing too.

Heading 06/14/2022PLUMBING ROUGH-INSTEVEN HEAD I-3598APPROVEDeTRAKiT Inspection Request6/14/2022 6:22:48 AM 6/14/2022 6:22 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 6/14/2022 9:44:09 AM Rough is good and piping can be backfilled in an effort to protect piping. Approval with held until the previously requested correction of site trash is provided. Refr to previous disapproval.

Heading 06/22/2022SLAB RESPAUL FONTENOTAPPROVEDeTRAKiT Inspection Request6/22/2022 6:09:26 AM 6/22/2022 6:09 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 09/06/2022PTO AND MECH ROUGHMIKE MCDONALD I-3343RES FAILEDDV left roof 4th from front9/6/2022 6:19:13 AM 9/6/2022 6:19 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 9/6/2022 2:46:14 PM mow all your lots, across the street, high weeds. set up wind fence on both sides. missing roof jacks and cap for furnace vent. fresh air intake must be 5' above shingles. low gas test. water under front shower pan. secure fireplace vent at roof. no pvc test.

Heading 09/09/2022PTO AND MECH ROUGHMIKE MCDONALD I-3343RES FAILEDeTRAKiT Inspection Request9/9/2022 6:43:33 AM 9/9/2022 6:43 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 9/9/2022 9:30:17 AM plumber registration has expired. still need to set up wind fence on both sides. still missing cap for furnace vent. still need to secure fireplace vent at roof.

Heading 09/13/2022PTO AND MECH ROUGHMIKE MCDONALD I-3343RES FAILEDeTRAKiT Inspection Request9/13/2022 6:48:16 AM 9/13/2022 6:48 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 9/13/2022 8:25:34 AM plumber registration still expired. still missing furnace vent cap. still need to secure FP vent at roof deck. 24hr hold, no reinspect until 9/15

Heading 09/15/2022PTO AND MECH ROUGHMIKE MCDONALD I-3343APPROVEDeTRAKiT Inspection Request9/14/2022 12:08:03 PM 9/14/2022 12:08 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 09/16/20222NDS AND FRAMINGDALTON FALLAWRES FAILEDeTRAKiT Inspection Request9/15/2022 3:13:49 PM 9/15/2022 3:13 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 9/16/2022 8:43:02 AM no third party inspection on site, no inspection completed

Heading 09/19/20222NDS AND FRAMINGDALTON FALLAWCANCELLEDeTRAKiT Inspection Request9/16/2022 12:27:03 PM 9/16/2022 12:27 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 9/19/2022 1:38:11 PM pay all fees

Heading 09/20/20222NDS AND FRAMINGDALTON FALLAWRES FAILEDeTRAKiT Inspection Request9/19/2022 2:43:26 PM 9/19/2022 2:43 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 9/20/2022 2:57:06 PM 1. Protect all raw wood front patio 2. Cut all cables to slab 3. Tape cuts in tply right side 4. Flash vent rear of house second story 5. Missing rear door 6. Missing tply rear of house next to master windows 7. Finish and flash garage portals 8. Flash electric at left front 9. Flash low voltage on both side of garage 10. Seal hot wall at double car garage 11. Correctly fire block side of stairs at electric 12. Fire block and seal top of chase at stairs with water line running through 13. Seal draft-stopping for 1000sq ft of subfloor 14. Drain all tubs and showers 15. Over bored studs at garage/ front left bedroom closet needs stud shoes 16. Poly seal electric at top plate in utility 17. Over bored gas line in garage needs (8) 10p nails on both side of top plate strap 18. Poly seal all penetrations into fireplace chase 19. Over notched studs at breakfast nook needs stud shoes 20. Fill all holes in structural straps at breakfast nook 21. Fire block and seal attic to subfloor communication at breakfast nook 22. Seal hot all at study Inspection stopped first floor only

Heading 09/28/20222NDS AND FRAMINGDALTON FALLAWRES FAILEDeTRAKiT Inspection Request9/27/2022 7:05:26 PM 9/27/2022 7:05 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 9/28/2022 1:46:57 PM prior tag items still not completed: 1,2,4,5,6,13,15,18,21,22 complete these items before walking second story

Heading 09/30/20222NDS AND FRAMINGDALTON FALLAWRES FAILEDeTRAKiT Inspection Request9/30/2022 6:30:10 AM 9/30/2022 6:30 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 9/30/2022 11:02:37 AM prior tag items: 2,3,4,6,15 Also 13 short studs at fireplace wall

Heading 10/05/20222NDS AND FRAMINGDALTON FALLAWAPPROVEDeTRAKiT Inspection Request10/4/2022 1:40:25 PM 10/4/2022 1:40 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 10/26/2022INSULATION RESGINNY QUEENCANCELLEDeTRAKiT Inspection Request10/25/2022 5:23:21 PM 10/25/2022 5:23 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 10/26/2022 10:20:57 AM clear safe path to house requested

Heading 10/27/2022INSULATION RESGINNY QUEENAPPROVEDeTRAKiT Inspection Request10/27/2022 6:08:25 AM 10/27/2022 6:08 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 11/04/2022BRICKWALL TIES RESGINNY QUEENAPPROVEDeTRAKiT Inspection Request11/3/2022 1:50:46 PM 11/3/2022 1:50 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 11/04/2022DRYWALL RESGINNY QUEENAPPROVEDeTRAKiT Inspection Request11/3/2022 1:53:24 PM 11/3/2022 1:53 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 12/07/2022FLATWORK RESJEFF ELLIS I-3380RES FAILEDeTRAKiT Inspection Request12/6/2022 3:07:58 PM 12/6/2022 3:07 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 12/7/2022 2:00:44 PM to wet. no further insp. on this street until it is cleaned.

Heading 12/15/2022FLATWORK RESJEFF ELLIS I-3380APPROVEDeTRAKiT Inspection Request12/14/2022 11:31:16 AM 12/14/2022 11:31 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 12/15/2022 3:20:10 PM p/u trash.

Heading 12/16/2022GAS RELEASEDEWAYNE CARTER I-3400APPROVEDeTRAKiT Inspection Request12/16/2022 6:51:00 AM 12/16/2022 6:51 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 01/09/2023ELECT FINAL RESJEFF ELLIS I-3380RES FAILEDeTRAKiT Inspection Request1/6/2023 12:12:29 PM 1/6/2023 12:12 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 1/9/2023 1:48:00 PM kitchen plugs out of the wall. missing switch in m. bdrm hallway.

Heading 01/13/2023ELECT FINAL RESJEFF ELLIS I-3380APPROVEDeTRAKiT Inspection Request1/13/2023 6:53:28 AM 1/13/2023 6:53 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 02/06/2023PLUMB MECH FINALCARLOS IRLAS I-3393CANCELLEDeTRAKiT Inspection Request2/3/2023 11:30:02 AM 2/3/2023 11:30 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 02/07/2023UTILITIES INSPECTIONTHOMAS LEALUTIL INSP FAILEDeTRAKiT Inspection Request2/3/2023 11:29:30 AM 2/3/2023 11:29 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 2/7/2023 10:19:35 AM remove mud out of meter can so that both meter nuts curb stop are fully exposed

Heading 02/10/2023UTILITIES INSPECTIONTHOMAS LEALAPPROVEDeTRAKiT Inspection Request2/8/2023 4:18:25 PM 2/8/2023 4:18 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 02/14/2023PLUMB MECH FINALCARLOS IRLAS I-3393RES FAILEDeTRAKiT Inspection Request2/14/2023 6:30:58 AM 2/14/2023 6:30 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 2/14/2023 8:45:41 AM can not see D/V vent, circuit breaker under sized, Paint all PVC and gas line, 1" clearance furnace vent pipe,

Heading 02/16/2023PLUMB MECH FINALCARLOS IRLAS I-3393RES FAILEDeTRAKiT Inspection Request2/16/2023 6:33:10 AM 2/16/2023 6:33 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 2/16/2023 3:26:37 PM 1" clearance furnace vent pipe and support gas liens at furnaces

Heading 02/21/2023PLUMB MECH FINALCARLOS IRLAS I-3393RES FAILEDeTRAKiT Inspection Request2/20/2023 9:26:05 PM 2/20/2023 9:26 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 2/21/2023 1:41:19 PM 1" clearance furnace #2vent pipe, replace gas flex line on furnace #2

Heading 02/23/2023PLUMB MECH FINALCARLOS IRLAS I-3393APPROVEDeTRAKiT Inspection Request2/22/2023 7:14:20 PM 2/22/2023 7:14 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com

Heading 02/24/2023CO AND BUILD FINALJOHN DRAPERCANCELLEDeTRAKiT Inspection Request2/23/2023 7:47:40 PM 2/23/2023 7:47 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 2/24/2023 2:47:02 PM Door locked - 10:49 am.

Heading 02/27/2023CO AND BUILD FINALJOHN DRAPERRES FAILEDeTRAKiT Inspection Request2/27/2023 6:44:42 AM 2/27/2023 6:44 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 2/27/2023 3:28:46 PM Jacuzzi tubs require a permanent access opening. Per the 2018 IRC - P2720.1 - "A door or panel shall be permitted to close the opening. The access opening shall be unobstructed and be of the size necessary to permit the removal and replacement of the circulation pump". E4209.4 - "Where the Hydro-massage bathtub is cord and plug-connected with the supply receptacle accessible only through a service access opening, the receptacle shall be installed so that its face is within direct view and not more than 12" from the plane of the opening".

Heading 03/01/2023CO AND BUILD FINALJOHN DRAPERRES FAILEDeTRAKiT Inspection Request3/1/2023 6:32:24 AM 3/1/2023 6:32 AM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com 3/1/2023 12:50:49 PM See notes from prior failed CO inspection. Pay fee.

Heading 03/02/2023CO AND BUILD FINALGINNY QUEENAPPROVEDeTRAKiT Inspection Request3/1/2023 4:14:15 PM 3/1/2023 4:14 PM SHADDOCK HOMES LTD Contact Name: SHADDOCK HOMES LTD Site Address: 6864 PADDINGTON LN Phone: 9725267700 e-Mail: permits@shaddockhomes.com