Permit Info
Short Description:
1 BF FIRE 5866 AC, 7203 SF, SFR / 2 STORY
Expiration Date:
4/21/2019
Notes:
1 BF FIRE 5866 AC, 7203 SF, SFR / 2 STORY
10/9/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
010. BEAMS=8"W X 28"D.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
046. SECOND STORY WINDOWS (SIZE & TYPE) MUST INCLUDE HEAD HEIGHT
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
055. WRITTEN COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO IN THE PERMIT POUCH.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 2BD, 2B, GAME
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
THE HILLS OF KINGSWOOD PH 1
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | JONES, JEANETTE | ()- | | | PLANO, TX 75025-3831 |
MAIL TO | JONES, JEANETTE | ()- | | | PLANO, TX 75025-3831 |
APPLICANT | MILAN DESIGN BUILD | (214)502-2014 | MJONES@MILANDESIGNBUILD.COM | | DALLAS, TX 75254 |
CONTRACTOR | MILAN DESIGN BUILD | (214)502-2014 | MJONES@MILANDESIGNBUILD.COM | | DALLAS, TX 75254 |
ELECT. CTR. | ARI-TEX ELECTRIC INC | (972)727-9902 | service@ari-tex.com | | ALLEN, TX 75013 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | ENERGY CODE SOLUTIONS | (817)412-0351 | ENERGYINSPECT@ATT.NET | | EULESS, TX 76040 |
MECH. CTR. | CHAPMAN AIR & HEAT | (214)340-4999 | aseutter@chapmanair.com | | DALLAS, TX 75238 |
PLUM. CONT. | RIDDELL PLUMBING INC | (972)682-4860 | chelsi@riddellplumbing.com | | MESQUITE, TX 75149 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/10/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
5/2/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/5/2018
| | 5/10/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/21/2017
| | 4/21/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/16/2017
| | 2/16/2017 | |
More Info
|
There are currently no reviews on this record.