Permit Info
Short Description:
1 BF FIRE PROT-563 AC, 7377 SF, SFR / 1 STORY
Expiration Date:
4/9/2019
Notes:
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
014. BEAMS=10"W X 30"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
027. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
030. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
043. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
046. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
1 BF FIRE PROT-563 AC, 7377 SF, SFR / 1 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
THE HILLS OF KINGSWOOD PH 1
|
BF TESTER | CHAD ADLER | (972)699-7156 | ADLERWATERWORKS@GMAIL.COM | 11305 KNOXVILLE LN | FRISCO, TX 75035 |
OWNER | PUCKETT, JEFFREY DAVID | ()- | | | FRISCO, TX 75034 |
MAIL TO | PUCKETT, JEFFREY DAVID | ()- | | | FRISCO, TX 75034 |
APPLICANT | DAVE R WILLIAMS HOMES LP | (972)346-2015 | CATHYW@DRWHOMES.COM | | PROSPER, TX |
CONTRACTOR | DAVE R WILLIAMS HOMES LP | (972)346-2015 | CATHYW@DRWHOMES.COM | | PROSPER, TX |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
FENCE | FAITH FENCE & FABRICATION INC | (214)728-6109 | RODNEYPLOCH@HOTMAIL.COM | | GUNTER, TX 75058 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)441-9795 | JMCDONALD@ENERGYINSPECTOR.COM | | MCKINNEY, TX 75071 |
MECH. CTR. | BILL JOPLINS COMPRESSOR SERVIC | (972)569-8339 | ywatkins@joplins.net | | McKINNEY, TX 75069 |
PLUM. CONT. | MEDLOCK SERVICES LLC | (972)562-4444 | NICK@MEDLOCKSERVICES.COM | | MCKINNEY, TX 75070 |
STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/22/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
5/10/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/7/2018
| | 5/10/2018 | |
More Info
|
BACKFLOW | APPROVED |
5/18/2017
| | 5/18/2017 | |
More Info
|
BACKFLOW | APPROVED |
4/9/2016
| | 4/9/2016 | |
More Info
|
There are currently no reviews on this record.