Permit Info
Short Description:
1 BF -FIRE PROT 5430 AC, 6564 SF, SFR / 2 STORY
Expiration Date:
4/3/2019
Notes:
1 BF -FIRE PROT 5430 AC, 6564 SF, SFR / 2 STORY
6/19/2014 12:00:00 AM
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
014. BEAMS=10"W X 30"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
027. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
040. TEMPERED GLASS REQ'D AT WINDOWS ADJACENT TO STAIRS
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
043. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
044. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
049. FUEL BURNING APPLIANCE INSTALLATION WITHIN AN AC AREA MUST BE CODE COMPLIANT.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2nd FLOOR: 3-BED ROOMS, 3-BATHS & GAME ROOM WITH A WET BAR.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
THE SHORES AT WATERSTONE PH 1
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | CALMERMAN, JAN S & ENAS JUDEH | ()- | | | FRISCO, TX 75034 |
MAIL TO | CALMERMAN, JAN S & ENAS JUDEH | ()- | | | FRISCO, TX 75034 |
APPLICANT | TGM HOMES INC | (214)796-5702 | THOMASG.MILLER@ATT.NET | | FRISCO, TX 75033 |
CONTRACTOR | TGM HOMES INC | (214)796-5702 | THOMASG.MILLER@ATT.NET | | FRISCO, TX 75033 |
ELECT. CTR. | ARI-TEX ELECTRIC INC | (972)727-9902 | service@ari-tex.com | | ALLEN, TX 75013 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
MECH. CTR. | STARN AIR INC | (214)221-1313 | STARNAIRINC@AOL.COM | | GARLAND, TX 75042 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/9/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
5/4/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
4/18/2016
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/7/2018
| | 5/9/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/3/2017
| | 4/3/2017 | |
More Info
|
BACKFLOW | APPROVED |
4/14/2016
| | 4/14/2016 | |
More Info
|
BACKFLOW | APPROVED |
4/17/2015
| | 4/17/2015 | |
More Info
|
There are currently no reviews on this record.