Permit Info
Short Description:
MULTIPURPOSE NO FIRE PROT - 5992 AC, 8140 SF, SFR / 2 STORY
Expiration Date:
4/18/2013
Notes:
MULTIPURPOSE NO FIRE PROT - 5992 AC, 8140 SF, SFR / 2 STORY
10/31/2011 12:00:00 AM
(10/31/2011 3:20 PM JC)
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. BEAMS=8"W X 24"D.
021. W/12" DIA. PIERS W/(2) #5 REBAR.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
047. RISERS MUST BE 7 3/4" MAXIMUM; TREAD MINIMUM OF 10". LANDING AS REQUIRED BY 2006 IRC.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(10/31/2011 3:21 PM JC)
MFD w/ piers
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
THE HILLS OF KINGSWOOD PH 1
|
| OWNER | CHU, CHI WAI & TSE-CHU, JENNIF | ()- | | | FRISCO, TX 75034 |
| MAIL TO | CHU, CHI WAI & TSE-CHU, JENNIF | ()- | | | FRISCO, TX 75034 |
| APPLICANT | MICHAEL & MELISSA LATHAM | (214)872-2105 | | | FRISCO, TX 75033 |
| CONTRACTOR | MICHAEL & MELISSA LATHAM | (214)872-2105 | | | FRISCO, TX 75033 |
| ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | PO BOX 13338 | ARLINGTON, TX 76094 |
| FIRE CONTACT | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | 900 ALPHA STE 430 | RICHARDSON, TX 75081 |
| HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | 3109 LUBBOCK AVENUE | FORT WORTH, TX 76109 |
| MECH. CTR. | ADVENT AIR CONDITIONING, INC | (972)221-4373 | mlewis@adventair.com | | LEWISVILLE, TX 75057 |
| PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
| STRUCT ENG | LOWELL CUMMINGS INC DBA LCI EN | (972)644-0882 | CUMMINGSOIKOS@SBCGLOBAL.NET | | RICHARDSON, TX 75082 |
| Total Fees |
|
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.
There are currently no reviews on this record.