Permit Info
Short Description:
1 BF FIRE PROT - 5908 AC, 7579 SF, SFR / 2 STORY
Status:
RES LETTER TWO SENT
Expiration Date:
4/19/2018
Notes:
1 BF FIRE PROT - 5908 AC, 7579 SF, SFR / 2 STORY
3/8/2011 12:00:00 AM
(3/8/2011 2:31 PM JC)
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. BEAMS=8"W X 30"D.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
032. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
051. WINDOW BOX-OUTS MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
(3/8/2011 2:31 PM JC)
(MFD)
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
THE HILLS OF KINGSWOOD PH 1
|
BF TESTER | JOSHUA D THOMPSON | (274)909-2877 | JOSH.THOMPSON@AFPGUSA.US | 7609 KALLAN DR | ROWLETT, TX 75089 |
OWNER | SCHUMACHER, DENNIS M JR | ()- | LDYE@GRANDHOMES.COM | | FRISCO, TX 75034 |
MAIL TO | SCHUMACHER, DENNIS M JR | ()- | LDYE@GRANDHOMES.COM | | FRISCO, TX 75034 |
APPLICANT | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #600 | DALLAS, TX 75248 |
CONTRACTOR | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #600 | DALLAS, TX 75248 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | STAFFORD, TX 77477 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | ACP ALLIED CONSTRUCTION PROFES | (214)227-9540 | TONYA@ENERGYACP.COM | 1900 ESPINOSA DRIVE | Carrollton, TX 75010 |
MECH. CTR. | PRO STAR AIR | (972)245-0700 | | 1225 E CROSBY RD #A-21 | CARROLLTON, TX 75006 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | JSANCHEZ@HORIZONPLUMBING.NET | 2706 WEST PIONEER PARKWAY | ARLINGTON, TX 76013 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | TAMI@STRANDSYSTEMS.COM | 6221 RIVERSIDE DRIVE #116 | IRVING, TX 75039 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/23/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
12/14/2011
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/23/2017
| | 6/23/2017 | |
More Info
|
BACKFLOW | APPROVED |
4/19/2016
| | 4/19/2016 | |
More Info
|
BACKFLOW | APPROVED |
12/12/2011
| | 12/12/2011 | |
More Info
|
There are currently no reviews on this record.