Permit Info
Short Description:
3713 AC, 4218 SF, SFR / 2 STORY
Notes:
3713 AC, 4218 SF, SFR / 2 STORY
12/9/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2nd FLOOR: 3-BED ROOMS, 2-BATH, GAME, MEDIA & DEN ROOMS.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
AUSTIN RIDGE AT LONE STAR RANCH
|
BF TESTER | CHRIS JONES | (214)597-1760 | | 1931 MIDDLE GLEN DR | CARROLLTON, TX 75007 |
OWNER | LANDON HOMES | (214)619-2930 | NWUSSOW@LANDONHOMESUSA.COM | 4050 W PARK BLVD | PLANO, TX 75093 |
APPLICANT | LANDON HOMES | (214)619-2930 | NWUSSOW@LANDONHOMESUSA.COM | 4050 W PARK BLVD | PLANO, TX 75093 |
CONTRACTOR | LANDON HOMES | (214)619-2930 | NWUSSOW@LANDONHOMESUSA.COM | 4050 W PARK BLVD | PLANO, TX 75093 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | STAFFORD, TX 77477 |
HERS PROVIDE | ACP ALLIED CONSTRUCTION PROFES | (214)227-9540 | TONYA@ENERGYACP.COM | 1900 ESPINOSA DRIVE | Carrollton, TX 75010 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | 900 ALPHA #430 | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
4/14/2011
| | 4/14/2011 | |
More Info
|
There are currently no reviews on this record.