Permit Info
Short Description:
3071 AC, 3671 SF, 2 STORY
Approved Date:
12/13/2024
Expiration Date:
7/12/2025
Notes:
12/5/2024 4:30:47 PM
Foundation Beam Size: 10"W X 28"D
Lot Specific Notes: S-4 OPEN FENCING REQUIRED ADJACENT TO STREET ON CORNER LOTS
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
LEXINGTON PARKS PHASE TEN (CFR)
|
APPLICANT | Monique Mendoza | (214)619-1070 | mmendoza@landonhomes.com | 4050 W Park Blvd | Plano, TX 75093 |
OWNER | LLC BR637 | ()- | | 4050 W PARK BLVD | PLANO, TX 75093-3839 |
CONTRACTOR | LANDON HOMES | (214)619-1070 | crussell@landonhomes.com | 4050 W PARK BLVD | PLANO, TX 75093 |
HERS PROVIDE | ENERGY CODE SOLUTIONS | (817)412-0351 | ENERGYINSPECT@ATT.NET | 1807 MARLENE DRIVE | EULESS, TX 76040 |
STRUCT ENG | CHILDRESS ENGINEERING (STRUCTURAL) | (214)451-6630 | HLENCKUS@CESGLOBAL.COM | 1701 N COLLINS BLVD STE 3000 | RICHARDSON, TX 75080 |
ELECT. CTR. | IES Residential (ELEC) | (972)562-7724 | brad.hargis@ies-co.com | 711 TOWER LANE | MCKINNEY, TX 75069 |
MECH. CTR. | AIRTRON INC. | (214)355-1210 | JULIA.ORTEGA@NRG.COM | 10440 OLYMPIC DR | DALLAS, TX 75220 |
PLUM. CTR. | L & S MECHANICAL (PLUMB) | (214)393-8339 | CITYREGISTRATION@LSMECH.COM | 1101 E. ARAPAHO RD, SUITE 190 | RICHARDSON, TX 75081 |
|
PERCENT CREDIT CARD FEE |
$15.10
|
12/13/2024
|
PLUMBING ROUGH-IN 12/31/2024 JWR |
$30.00
|
|
1 INCH PD METER |
$605.00
|
12/13/2024
|
WATER METER DEPOSIT |
$150.00
|
12/13/2024
|
AUTO PROCESSING FEE |
$6.00
|
12/2/2024
|
FENCE FEE |
$20.00
|
12/13/2024
|
Z-FIELDS REIMBURSEMENT FEE |
$0.00
|
|
RESIDENTIAL NEW PERMIT FEE |
$1,286.43
|
12/13/2024
|
RESIDENTIAL FEE |
$110.13
|
12/13/2024
|
RESIDENTIAL MECHANICAL FEE |
$122.00
|
12/13/2024
|
RESIDENTIAL NEW APPLICATION FEE |
$300.00
|
12/2/2024
|
RESIDENTIAL PLUMBING FEE |
$170.00
|
12/13/2024
|
SEWER IMPACT FEE |
$2,344.00
|
12/13/2024
|
THOROUGHFARE IMPACT FEE |
$0.00
|
|
WATER IMPACT FEE |
$2,144.00
|
12/13/2024
|
AUTO PROCESSING FEE |
$123.93
|
12/13/2024
|
Total Fees |
Charged: $7,426.59
Balance Due: $30.00
|
|
SLAB RES | APPROVED |
1/13/2025
| | 1/13/2025 | |
More Info
|
PLUMBING ROUGH-IN | APPROVED |
1/7/2025
| | 1/7/2025 | |
More Info
|
PLUMBING ROUGH-IN | RES FAILED |
1/6/2025
| | 1/6/2025 | |
More Info
|
PLUMBING ROUGH-IN | RES FAILED |
1/2/2025
| | 1/2/2025 | |
More Info
|
PLUMBING ROUGH-IN | RES FAILED |
12/31/2024
| | 12/31/2024 | |
More Info
|
SET 1 PD METER | APPROVED |
12/31/2024
| | 12/31/2024 | |
More Info
|
T-POLE RES | APPROVED |
12/23/2024
| | 12/23/2024 | |
More Info
|
METER PAYMENT | APPROVED |
12/13/2024
| | 12/13/2024 | |
More Info
|