Permit Info
Short Description:
2064 AC, 2917 SF, SFR / 3 STORY
Expiration Date:
10/3/2019
Notes:
3/8/2019 5:15:05 PM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
014. BEAMS=10"W X 28"D.
025. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
033. ALL SIDING,TRIM,SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
038. STAIR VERTICAL RISE OF 147(R311.7.3) OR GREATER REQUIRES AN INTERMEDIATE LANDING
040. TEMPERED GLASS REQUIRED AT STAIR LANDING WINDOW(S).
043. TEMPERED GLASS REQUIRED AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS. EMERGENCY/ESCAPE RESCUE OPENINGS SHALL HAVE NET CLEAR OPENING OF GREATER THAN OR EQUAL TO 5.7 SF. MINIMUM NET CLEAR HEIGHT OF 24" AND NET CLEAR WIDTH OF 20" (GRADE FLOOR OR BELOW GREATER THAN OR EQUAL TO 5.0SF).
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND AND ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN AND INSTALLATION APPROVED BY FIRE MARSHAL.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
GABLES AT OHIO (CFR)
|
APPLICANT | MEGATEL HOMES INC | (214)614-8664 | PERMITDOCS@MEGATELHOMES.COM | | FARMERS BRANCH, TX 75234 |
OWNER | MEGATEL GABLES LLC | ()- | | | DALLAS, TX 75234-8923 |
CONTRACTOR | MEGATEL HOMES INC | (214)614-8664 | PERMITDOCS@MEGATELHOMES.COM | | FARMERS BRANCH, TX 75234 |
ENGINEER | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)235-9395 | JMCDONALD@ENERGYINSPECTORS.COM | | MCKINNEY, TX 75070 |
STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
ELECT. CTR. | IES RESIDENTIAL INC (ELEC) | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
MECH. CTR. | AIRTRON INC. | (972)272-9633 | kellyn.haughwout@directenergy.com | | DALLAS, TX 75220 |
PLUM. CONT. | GOLD STANDARD PLUBMING, LLC | (210)566-4325 | JESS.TORRES@GMAIL.COM | | CIBOLO, TX 78108 |
|
RESIDENTIAL BUILDING PERMIT FEE |
$1,263.75
|
|
RESIDENTIAL FEE |
$87.51
|
|
FENCE FEE |
$20.00
|
|
RESIDENTIAL PLUMBING FEE |
$233.00
|
|
RESIDENTIAL MECHANICAL FEE |
$113.00
|
|
THOROUGHFARE IMPACT FEE |
$0.00
|
|
SEWER IMPACT FEE |
$1,619.00
|
|
WATER IMPACT FEE |
$1,939.00
|
|
Total Fees |
Charged: $5,275.26
Balance Due: $5,275.26
|
There are currently no inspections on this record.
|
INITIAL REVIEW | KELLY EVANS | ACCEPTED | 2/19/2019 | 2/19/2019 | 3/5/2019 |
More Info
|
RESIDENTIAL REVIEW | CAREY L FRAZIER | APPROVED AS NOTED | 2/19/2019 | 3/8/2019 | 3/5/2019 |
More Info
|